Graco XM Series Operation page 69

Plural-component sprayers
Hide thumbs Also See for XM Series:
Table of Contents

Advertisement

Alarm
Code
Alarm Problem
*P2AX
Pressure exceeded
P2BX
advisory limits.
*QPDX
Pot life timer expired.
Mixed fluid will cure in
hoses, mixer, and gun.
*T2DA
Temperature exceeded
T2DB
advisory limits.
*T5DA
Temperature exceeded
T5DB
alarm limits.
312359R
When Active
Optional User-Settable Spray Limits
Spray
Pressure exceeded high or
low advisory limits for more
than 15 seconds.
Spray
Have not sprayed enough
volume to keep fresh mixed
fluid in the integration hose,
mixer, whip hose, and spray
gun.
Spray
Fluid temperature exceeded
high or low limits for more than
four minutes.
Spray
Fluid temperature exceeded
high or low alarm limits for
more than four minutes.
Cause
Same as P5A or P5B above.
Spray fluid, or flush. Resets when
you leave spray mode. Follow
Spray, page 41, or Flush, page
44.
Same as T5A or T5B above.
If fluid temperature is too low,
return to circulation mode to
increase fluid temperature. Adjust
heater set point if needed. Follow
Heat Fluid, page 40.
If fluid temperature is too high,
lower heater set point, and return
circulation mode to cool. Follow
Heat Fluid, page 40.
Adjust temperature target setpoint.
Follow Heat Fluid, page 40.
Troubleshooting
Solution