Setup
XM _ M _ _ , XM _ H _ _ , XM _ J _ _ , and
XM _ K _ _ Models
For sprayers with junction boxes to include 230V-480V.
All electrical wiring must be done by a qualified
electrician and comply with all local codes and
regulations.
Use the intended entry locations shown in Junction
Box, page 22.
1. Turn the main power switch (BB) Off.
2. Open the junction box door.
3. Non-Hazardous Locations only: Route the power
cord through the strain relief (BH) into the electrical
enclosure
(BA).
Hazardous Locations only: Follow local codes
and regulations for routing the power cord through
the main power entry point (BG) electrical enclosure
(BA).
28
4. Connect the ground wire to ground terminal (GT).
See F
. 7, page 29.
IG
5. Connect the power cord to the disconnect as shown
in the F
. 7, page 29. Tighten conductors to 55 in-lb
IG
(6.2 N•m). Gently pull on all connections to verify
that they are properly secured.
6. Non-Hazardous Locations only: Tighten strain
relief (BH).
Hazardous Locations only: Follow local codes
and regulations for sealing the power cable entering
into the enclosure.
7. Install the supplied terminal jumpers in the positions
shown in the F
. 7, page 29.
IG
8. Verify that all items are connected properly as
shown in the F
. 7, page 29, then close the junction
IG
box door.
NOTE: The machine is provided with jumpers in the 380
Vac 3-Phase Wye position.
NOTE: Jumpers are only applicable with 230V-380V.
312359R