Pump Package Performance Charts

Calculate Fluid Outlet Pressure
To calculate fluid outlet pressure (psi/MPa/bar) at a spe-
cific fluid flow (gpm/lpm) and operating air pressure
(psi/MPa/bar), use the following instructions and pump
data charts.
1. Locate desired flow along bottom of chart.
2. Follow vertical line up to intersection with selected
fluid outlet pressure curve. Follow left to scale to
read fluid outlet pressure.
Key: Air Pressure
A
100 psi (0.7 MPa, 7 bar)
B
70 psi (0.5 MPa, 7.8 bar)
C
40 psi (0.3 MPa, 2.8 bar)
Dashed lines indicate low noise motors.
16:1 Xtreme Pumps
1600
A
(11.2, 112)
1200
(8.4, 84)
B
800
(5.6, 56)
C
400
(2.8, 28)
0
1.0
(3.8)
Fluid Flow in gpm (lpm)
24:1 Xtreme Pumps
2500
A
(17.5, 175)
B
1500
(10.5, 105)
C
500
(3.5, 35)
1.0
0
(3.8)
Fluid Flow in gpm (lpm)
311164M
80
(2.2)
A
60
(1.7)
B
40
(1.1)
C
20
(0.6)
2.0
4.0
3.0
(7.6)
(15.2)
(11.4)
80
(2.2)
A
60
(1.7)
B
40
(1.1)
20
C
(0.6)
2.0
3.0
(7.6)
(11.4)
Pump Package Performance Charts
Calculate Pump Air Flow/Consumption
To calculate pump air flow/consumption (scfm or
3
m
/min) at a specific fluid flow (gpm/lpm) and air pres-
sure (psi/MPa/bar), use the following instructions and
pump data charts.
1. Locate desired flow along bottom of chart.
2. Follow vertical line up to intersection with selected
air flow/consumption curve. Follow right to scale to
read air flow/consumption.
21:1 Xtreme Pumps
2500
(17.5, 175)
A
1500
B
(10.5, 105)
C
500
(3.5, 35)
0
Fluid Flow in gpm (lpm)
25:1 Xtreme Pumps
2500
A
(17.5, 175)
B
1500
(10.5, 105)
C
500
(3.5, 35)
0
1.0
(3.8)
Fluid Flow in gpm (lpm)
A
B
C
2.0
1.0
3.0
(7.6)
(3.8)
(11.4)
A
80
B
(2.2)
C
3.0
5.0
(11.4)
(19.0)
80
(2.2)
60
(1.7)
40
(1.1)
20
(0.6)
160
(4.5)
120
(3.4)
40
(1.1)
57