Download Print this page

Omron E5 N-H Series Manual page 65

Digital temperature controllers/digital controllers
Hide thumbs Also See for E5 N-H Series:

Advertisement

Power ON
Manual Control
Level
Operation
Protect Level
Level
Initial Setting
Level
Advanced
Function Setting
Level
Press the O Key for at least 1 s.
Advanced Function Setting Level
init
o-dp
Parameter Initialization
off
off
M
M
spru
ret
SP Ramp Time Unit
m
off
M
M
a1lt
rest
Standby Sequence
Reset
a
off
M
M
sb1n
a2lt
Auxiliary Output 1
Open in Alarm
n-o
off
M
M
a3lt
sb2n
Auxiliary Output 2
n-o
Open in Alarm
off
M
M
prlt
sb3n
Auxiliary Output 3
Open in Alarm
n-o
3
M
M
sero
hbu
HB ON/OFF
off
on
M
M
cjc
hbl
Heater Burnout
Latch
on
off
M
M
hbh
rlrv
Heater Burnout
Hysteresis
off
0.1
M
M
colr
st-b
c
ST Stable Range
red
15.0
M
M
α
pv-b
alfa
c
5.0
0.65
M
M
a1on
at-g
AT Calculated Gain
0
1.0
M
M
a2on
at-h
c
AT Hysteresis
0
0.8
M
M
a3on
lcma
Limit Cycle MV
Amplitude
0
20.0
M
M
a1of
inf
Input Digital Filter
0
0
0.0
M
M
a2of
pvad
Additional PV Display
0
off
M
M
a3of
0
M
Adjustment
Bank Setting
Level
Level
Communica-
tions Setting
Level
istp
Input Shift Type
MV Display
ins1
M
mvse
Automatic Display
MV at Stop and Error
Return Time
Addition
off
M
amad
Auto/Manual Select
Alarm 1 Latch
Addition
on
M
rt
RT
Alarm 2 Latch
off
M
hsu
HS Alarm Use
Alarm 3 Latch
on
M
hsl
Move to Protect Level
HS Alarm Latch
Time
off
M
hsh
Input Error Output
HS Alarm Hysteresis
0.1
M
lba
LBA Detection Time
Cold Junction
Compensation
0
Method
M
lbal
MB Command
c
LBA Level
Logic Switching
8.0
M
lbab
c
PV Change Color
LBA Band
3.0
M
out1
PV Stable Band
Control Output 1
Assignment
o
M
out2
Alarm 1 ON Delay
Control Output 2
Assignment
none
M
Alarm 2 ON Delay
sub1
Auxiliary Output 1
Assignment
alm1
M
Alarm 3 ON Delay
sub2
Auxiliary Output 2
Assignment
alm2
M
Alarm 1 OFF Delay
sub3
Auxiliary Output 3
Assignment
alm3
(E5AN/E5EN-H only)
M
Alarm 2 OFF Delay
csel
Character Select
on
M
Alarm 3 OFF Delay
t-u
Soak Time Unit
m
M
E5@N/E5@N-H
PID Setting
Monitor/Setting
Item Level
Level
pfd1
alsp
Alarm SP Selection
Monitor/Setting Item 1
sp-m
1
M
M
rspu
pfd2
Monitor/Setting Item 2
Remote SP Enable
off
0
M
M
rsph
pfd3
c
Remote SP
Monitor/Setting Item 3
Upper Limit
1300.0
0
M
M
rspl
Remote SP
pfd4
c
Monitor/Setting Item 4
Lower Limit
-200.0
0
M
M
sptr
pfd5
SP Tracking
Monitor/Setting Item 5
off
0
M
M
rseo
Remote SP Input
spdp
"PV/SP" Display
Error Output
Screen Selection
off
4
M
M
pidi
PID Set Automatic
odsl
MV Display Selection
Selection Data
pv
o
M
M
pidh
PID Set Automatic
pvdp
PV Decimal Point
Selection Hysteresis
Display
0.50
on
M
M
p-db
c
PV Dead Band
pvst
PV Status Display
Function
0.0
off
M
M
manl
Manual MV
svst
SV Status Display
Limit Enable
off
Function
off
M
M
pmvd
Direct Setting of
d.ref
Display Refresh
Position Proportional MV
off
Period
0.25
M
M
pvrp
PV Rate of Change
ra1m
Control Output 1
Calculation Period
ON/OFF Count
17
0
Monitor
M
M
csca
Automatic Cooling
ra2m
Control Output 2
off
Coefficient Adjustment
ON/OFF Count
0
Monitor
M
M
ocu
Heater Overcurrent
ra1
Control Output 1
on
ON/OFF Count
Use
0
Alarm Set Value
M
M
ocl
Heater Overcurrent
Control Output 2
ra2
ON/OFF Count
Latch
off
0
Alarm Set Value
M
M
och
Heater Overcurrent
rac
ON/OFF Counter
Hysteresis
Reset
0.1
0
M
M
pf
PF Setting
cmov
Move to Calibration
a-m
Level
0
M
M
65

Advertisement

loading

This manual is also suitable for:

E5 n seriesE53-cnbn2E53-cn03n2E53-cnhbn2