USB-Serial Conversion Cable
Applicable OS
Applicable software
Applicable models
USB interface standard
DTE speed
Connector specifications
Power supply
Power supply voltage
Current consumption
Ambient operating tempera-
ture
Ambient operating humidity 10% to 80%
Storage temperature
Storage humidity
Altitude
Weight
Note: A driver must be installed in the personal computer. Refer to
installation information in the operation manual for the
Conversion Cable.
Communications Specifications
Transmission line
RS-485, RS-422: Multipoint
connection method
RS-232C: Point-to-point
RS-485 (two-wire, half duplex)
Communications
RS-422 (four-wire, half duplex) or RS-232C
Synchronization
Start-stop synchronization
method
Protocol
CompoWay/F, SYSWAY, or Modbus
1200, 2400, 4800, 9600, 19200, 38400, or
Baud rate
57600 bps
ASCII (CompoWay/F, SYSWAY)
Transmission code
RTU (Modbus)
Data bit length ✽
7 or 8 bits
Stop bit length ✽
1 or 2 bits
Vertical parity (none, even, odd)
Frame check sequence (FCS) with SYSWAY
Error detection
Block check character (BCC) with
CompoWay/F or CRC-16 Modbus
Flow control
None
Interface
RS-485, RS-422, or RS-232C
Retry function
None
Communications
217 bytes
buffer
Communications
0 to 99 ms
response wait time
Default: 20 ms
Note: The baud rate, data bit length, stop bit length, and vertical parity
can be individually set using the Communications Setting
Level.
Windows 2000, XP, or Vista
Thermo Mini, CX-Thermo version
4.0 or higher
E5AN/E5EN/E5CN/E5CN-U/
E5AN-H/E5EN-H/E5CN-H
Conforms to USB Specification 1.1.
38400 bps
Computer: USB (type A plug)
Temperature Controller: Setup
Tool port (on bottom of Controller)
Bus power (Supplied from USB
host controller.)
5 VDC
70 mA
0 to 55°C (with no condensation or
icing)
−20 to 60°C (with no condensation
or icing)
10% to 80%
2,000 m max.
Approx. 100 g
Current Transformer (Order Separately)
Ratings
Dielectric strength
Vibration resistance
Weight
Accessories (E54-CT3 only) Armatures (2)
USB-Infrared Conversion Cable
Applicable OS
Applicable software
Applicable models
USB interface standard
DTE speed
Connector specifications
Power supply
Power supply voltage
Current consumption
Ambient operating tempera-
ture
Ambient operating humidity 10% to 80%
Storage temperature
Storage humidity
Altitude
Weight
Note: A driver must be installed in the personal computer. Refer to
installation information in the operation manual for the
Conversion Cable.
Heater Burnout Alarms, SSR Failure
Alarms, and Heater Overcurrent Alarms
Models with detection for single-phase
CT input
heaters: One input
(for heater current detec-
Models with detection for single-phase
tion)
or three-phase heaters: Two inputs
Maximum heater current
50 A AC
Input current indication
±5% FS ±1 digit max.
accuracy
Heater burnout alarm set-
0.1 to 49.9 A (in units of 0.1 A)
ting range ✽1
Minimum detection ON time: 100 ms
SSR failure alarm setting
0.1 to 49.9 A (in units of 0.1 A)
range ✽2
Minimum detection OFF time: 100 ms
Heater overcurrent alarm
0.1 to 49.9 A (in units of 0.1 A)
setting range ✽3
Minimum detection ON time: 100 ms
✽1. For heater burnout alarms, the heater current will be measured when
the control output is ON, and the output assigned to the alarm 1
function will turn ON if the heater current is lower than the set value
(i.e., heater burnout detection current value).
✽2. For SSR failure alarms, the heater current will be measured when the
control output is OFF, and the output assigned to the alarm 1 function
will turn ON if the heater current is higher than the set value (i.e., SSR
failure detection current value).
✽3. For heater overcurrent alarms, the heater current will be measured
when the control output is ON, and the output assigned to the alarm 1
function will turn ON if the heater current is higher than the set value
(i.e., heater overcurrent detection current value).
E5AN-H/E5EN-H
1,000 VAC for 1 min
2
50 Hz, 98 m/s
E54-CT1: Approx. 11.5 g,
E54-CT3: Approx. 50 g
Plugs (2)
Windows 2000, XP, or Vista
Thermo Mini, CX-Thermo version
4.0 or higher
E5AN-H/E5EN-H
Conforms to USB Specification 1.1.
38400 bps
Computer: USB (type A plug)
Temperature Controller: Infrared
port (on front of Controller)
Bus power (Supplied from USB
host controller.)
5 VDC
80 mA
0 to 55°C (with no condensation or
icing)
−20 to 60°C (with no condensation
or icing)
10% to 80%
2,000 m max.
Approx. 130 g (with mounting
adaptor)