Omron E5 N-H Series Manual page 63

Digital temperature controllers/digital controllers
Hide thumbs Also See for E5 N-H Series:

Advertisement

Press the PF Key
for at least 1 s.
Press the O Key less than 1 s.
Adjustment Level
Adjustment Level
Display
l.adj
Displayed only
p
c
once when
8.0
entering
adjustment level.
M
M
at
i
AT Execute/Cancel
off
233.0
M
M
cmwt
d
Communications
off
40.0
Writing
M
M
c-sc
irda
Infrared Communications Use
1.00
off
M
M
c-db
spmd
SP Mode
0.0
lsp
M
M
of-r
ct1
Heater Current 1
50.0
0.0
Value Monitor
M
M
hys
hb1
Heater Burnout
1.0
0.0
Detection 1
M
M
chys
oc1
Heater Overcurrent
1.0
50.0
Detection 1
M
M
soak
ct2
Heater Current 2
0.0
Value Monitor
M
M
wt-b
hb2
Heater Burnout
off
0.0
Detection 2
M
M
mv-s
oc2
Heater Overcurrent
0.0
50.0
Detection 2
M
M
mv-e
lcr1
Leakage Current 1
0.0
0.0
Monitor
M
M
sprt
hs1
off
HS Alarm 1
50.0
M
M
ol-h
lcr2
Leakage Current 2
105.0
0.0
Monitor
M
M
ol-l
hs2
-5.0
HS Alarm 2
50.0
M
M
orl
ins
c
Temperature Input Shift
0.0
0.00
M
M
1-point shift
db
Set either
insh
c
Upper Limit
of these
2.0
Temperature
param-
0.00
Input Shift Value
eters.
M
M
2-point shift
oc-h
insl
c
Lower Limit
0.8
Temperature
0.00
Input Shift Value
M
M
sqrp
0.0
M
✽1. When the PF Setting parameter is set to A-M for a Controller with a PF Key (E5AN-H/E5EN-H).
✽2. When the PF Setting parameter is set to PFDP for a Controller with a PF Key (E5AN-H/E5EN-H).
Starting in manual mode.
Manual Control Level
PID
25.0
c
Control
100.0
only
✽1
PV/MV
25.0
c
Proportional Band
M
25.0
c
0.0
Integral Time
M
PID settings
a-m
Press
Derivative Time
the O
M
Key for
at least
bank
3 s.
0
Cooling Coefficient
M
Heating/cooling
rsp
c
0.0
Dead Band
M
sp-m
Manual Reset Value
Clear the offset during
0.0
stabilization of P or PD
control.
M
ct1
Hysteresis (Heating)
0.0
M
Hysteresis settings
ct2
Hysteresis (Cooling)
0.0
M
lcr1
Soak Time
1
0.0
M
lcr2
Wait Band
0.0
M
prst
MV at Stop
rset
M
sktr
MV at PV Error
0
M
SP Ramp Set Value
MV Upper Limit
MV Lower Limit
PF Key ✽2
Monitor/Setting Item Level
MV Change Rate Limit
Position Proportional
25.0
Monitor/Setting
Dead Band
Item Display 1
0.0
Open/Close Hysteresis
Extraction of Square
Root
Note: The monitor/setting items to be displayed is set in the Monitor/Setting Item 1 to
Low-cut Point
5 parameters (advanced function setting level).
E5@N/E5@N-H
Power ON
Press the O
Starting in
Key or the PF
automatic
Key for at least
mode.
1 s. ✽1
Operation Level
r-s
Process Value
Added when Additional
RUN/STOP
run
PV display is ON.
M
al-1
c
Process Value/
Alarm Value 1
Set Point
0.0
M
al1h
Auto/Manual Switch
c
Alarm Value
PID control only.
0.0
Upper Limit 1
Added when
auto/manual select
M
addition is ON.
al1l
c
Bank No.
Alarm Value
0.0
Lower Limit 1
M
al-2
c
Remote SP Monitor
Alarm Value 2
0.0
M
al2h
c
Set Point During
Alarm Value
0.0
SP Ramp
Upper Limit 2
M
al2l
c
Alarm Value
Heater Current 1 Value
Lower Limit 2
0.0
Monitor
M
al-3
c
Heater Current 2 Value
Alarm Value 3
0.0
Monitor
M
al3h
Alarm Value
Leakage Current 1
0.0
Upper Limit 3
Monitor
M
al3l
Alarm Value
Leakage Current 2
Lower Limit 3
0.0
Monitor
M
o
MV Monitor (Heating)
Program Start
0.0
M
c-o
Soak Time Remain
MV Monitor (Cooling)
0.0
M
v-m
Valve Opening
Monitor
0.0
M
(E5AN-H/E5EN-H only)
Monitor/Setting
PF
PF
Item Display 2
Monitor/Setting
Monitor/Setting
PF
Item Display 4
Item Display 5
PF Key
Press the O
and M Keys for
at least 3 s.
Press the O
and M Keys for
at least 1 s.
Monitor/Setting
Item Display 3
PF
✽2
63