Omron E5 N-H Series Manual page 60

Digital temperature controllers/digital controllers
Hide thumbs Also See for E5 N-H Series:

Advertisement

E5@N/E5@N-H
Parameters
Basic Type
Some parameters are not displayed depending on
the model of the Controller and parameter settings.
For details, refer to the E5CN/E5AN/E5EN Digital
Temperature Controllers User's Manual Basic Type
(Cat. No. H156).
Press the PF Key for
at least 1 s. ✽1
Press the O Key less than 1 s.
Adjustment
Level
Press the O Key less than 1 s.
Adjustment Level
Display
Displayed only
C
l.adj
once when
entering
adjustment level.
M
at
C
insh
AT Execute/Cancel
off
M
cmwt
C
Communications
Writing
off
M
ct1
C
Heater Current 1
Value Monitor
0.0
M
hb1
Heater Burnout
Detection 1
0.0
M
oc1
Heater Overcurrent
Detection 1
50.0
M
c-sc
ct2
Heater Current 2
Value Monitor
0.0
M
hb2
c-db
C
Heater Burnout
Detection 2
0.0
M
oc2
of-r
Heater Overcurrent
Detection 2
50.0
M
lcr1
C
Leakage Current 1
Monitor
0.0
0.0
M
chys
hs1
C
HS Alarm 1
50.0
M
lcr2
Leakage Current 2
Monitor
0.0
M
wt-b
C
hs2
HS Alarm 2
50.0
M
mv-s
sp-0
C
SP 0
0
M
mv-e
C
sp-1
SP 1
0
SP used by
M
multi-SP
C
sp-2
C
SP 2
0
M
ol-h
sp-3
C
SP 3
0
M
sqrp
60
Starting in manual mode.
Manual Control Level
25
C
PV/MV
ins
Temperature Input Shift
0.0
M
1-point shift
Set either
Upper Limit
of these
Temperature
0.0
parameters.
Input Shift Value
Press the
M
2-point shift
O Key
insl
Lower Limit
for at
Temperature
least 3 s.
0.0
Input Shift Value
M
p
Proportional Band
8.0
M
i
Integral Time
233
M
PID settings
d
Derivative Time
40
M
Cooling Coefficient
M
Heating/cooling
Dead Band
0.0
M
Manual Reset Value
Clear the offset during
50.0
stabilization of P or PD
control.
M
hys
Hysteresis (Heating)
1.0
M
Hysteresis settings
Hysteresis (Cooling)
1.0
M
soak
Soak Time
Press the O and M Keys for
1
at least 3 s.
M
Wait Band
off
Note: The time taken to move to the protect
M
MV at Stop
0.0
pmov
M
M
MV at PV Error
0.0
oapt
M
sprt
SP Ramp Set Value
off
icpt
M
MV Upper Limit
105.0
wtpt
M
ol-l
MV Lower Limit
-5.0
M
pfpt
orl
MV Change Rate Limit
0.0
pmsk
M
Extraction of Square Root
Low-cut Point
0.0
prlp
M
Power ON
Starting in
automatic
mode.
Press the O
Key or the PF
PID
Control
Key for at least
only
1 s.
✽1
Operation Level
r-s
25
C
RUN/STOP
Process Value
Added when Additional
run
PV display is ON.
M
M
25
C
al-1
Process Value/
C
Alarm Value 1
Set Point
0
0
M
M
a-m
Auto/Manual Switch
al1h
C
Alarm Value
PID control only.
Upper Limit 1
Added when
0
auto/manual select
M
M
addition is ON.
m-sp
al1l
C
Multi-SP
Alarm Value
Set Point Setting
Lower Limit 1
0
0
M
M
sp-m
al-2
C
Set Point During
C
Alarm Value 2
SP Ramp
0
0
M
M
ct1
al2h
Heater Current 1 Value
C
Alarm Value
Monitor
Upper Limit 2
0.0
0
M
M
ct2
al2l
Alarm Value
Heater Current 2 Value
C
Lower Limit 2
Monitor
0.0
0
M
M
lcr1
al-3
Alarm Value 3
C
Leakage Current 1
Monitor
0.0
0
M
M
lcr2
al3h
Leakage Current 2
C
Alarm Value
Monitor
Upper Limit 3
0.0
0
M
M
prst
al3l
Alarm Value
Program Start
C
Lower Limit 3
rset
0
M
M
sktr
Soak Time Remain
o
MV Monitor (Heating)
0
0.0
M
M
c-o
MV Monitor (Cooling)
0.0
M
Press the O and M Keys for at least 1 s.
Communications
Protect Level
Setting Level
Note: Displayed only for models with communications.
level can be adjusted by changing the
Changes are effective after cycling power or
after a software reset.
"Move to protect level time" setting.
Move to Protect Level:
psel
Displayed only when a password
0
is set. Restricts moving to protect
cwf
level.
M
Operation/Adjustment Protect:
u-no
Restricts displaying and
modifying menus in operation,
0
1
adjustment, and manual control
M
M
levels.
Initial Setting/
bps
Communications Protect:
This protect level restricts movement
9.6
1
to the initial setting, communications
M
M
setting, and advanced function setting
levels.
len
Setting Change Protect:
Protects changes to setups by
7
off
operating the front panel keys.
M
M
sbit
PF Key Protect
Restricts PF key operation
2
off
(E5AN/E5EN only)
M
M
prty
Parameter Mask Enable:
Displayed only when a
even
on
parameter mask is set.
M
M
sdwt
Password to Move to Protect Level:
Password setting
0
20
M
M
PF Key ✽2
Press the O Key for at least 3 s.
Other than the Auto/Manual Switch display
Initial Setting Level
Press the O Key less than 1 s.
Press the
O Key for
at least 1 s.
in-t
5
M
in-h
100
M
in-l
0
M
dp
0
M
d-u
c
M
sl-h
C
1300
M
sl-l
C
M
cntl
onof
M
s-hc
stnd
M
st
on
M
ptrn
off
M
cp
20
M
c-cp
20
M
orev
or-r
M
Press the O Key
alt1
less than 1 s.
2
M
alh1
C
0.2
M
Protocol Setting:
Switches between
CompoWay/F (SYSWAY)
and Modbus.
Communications Unit No.
Communications
Baud Rate
CompoWay/F
✽1. When the PF Setting
(SYSWAY) only
parameter is set to A-M for a
Communications
Data Length
Controller with a PF Key
(E5AN/E5EN).
Communications
Stop Bits
✽2. When the PF Setting
parameter is set to PFDP for a
Communications Parity
Controller with a PF Key
(E5AN/E5EN).
Send Data Wait Time
✽2
PF Key
Input Type
Scaling Upper Limit
Scaling Lower Limit
Decimal Point
For input type of analog
Temperature Unit
°C, °F
For input type of
temperature
SP Upper Limit
Limit the set point
SP Lower Limit
PID ON/OFF
Standard or
Heating/Cooling
ST (Self-tuning)
For input type of
temperature, standard
control, or PID
Program Pattern
When assigning PID or
control output to ON/OFF
output
Control Period (Heating)
Set the ON/OFF
output cycle.
Control Period (Cooling)
Direct/Reverse Operation
Alarm 1 Type
Alarm 1
Hysteresis