Enter (if applicable) the partition number 1 or 2 (or 0 for any).
02 Start:
Part
Press the [ ] key to continue.
Any Partition
A
If a zone list will be used to STOP, or restore, the device action, enter the zone
02 Stop:
Zn List
list number 1, 2, or 3 (to be programmed in 81 mode). If not used, enter 0.
No List
0
If a zone type or system operation will be used to STOP the device action,
02 Stop:
Zn Typ
enter the appropriate two digit code (see the "ZT" choices listed above). If not,
Not Used
00
enter 00. Press the [ ] key to continue.
Enter (if applicable) the partition number 1 or 2 (or 0 for any). Press the [ ]
02 Stop:
Part
key to continue.
Any Partition
A
This screen again displays a summary of the current device START
02
A EV ZL ZT P
programming . Press the [ ] key to continue.
STT 0 0 0 00 1
This screen again displays a summary of the current device STOP
02
A EV ZL ZT P
programming. Press the [ ] key to continue.
STP – – 0 00 A
Enter 1 if using a Powerline Carrier Device (X-10); if not, enter 0.
02 X10 Device ?
The display then returns again to the first screen so that the next device
0 = No, 1 = Yes 00
number to be programmed can be entered, or enter [0][0] to end device
programming.
Example of
A lamp is to be turned on via a Powerline Carrier device (X-10) when any one
Output Device
of 3 specific zones are faulted, or when any 24-hour auxiliary zone is faulted.
Programming
We want to be able to turn off the lamp manually without affecting the
arming status of the system.
To program this, we would do the following:
¥ In
¥ The second condition for turning on the indicator is triggering a 24-hour
¥ Next, enter the Partition number (P) in which you want the triggering of a
¥ To stop the Device action and turn off the lamp, we do not want to use a
¥ The system will display a summary screen for the START programming
¥ The system will display a summary screen for the STOP programming for
¥ The system will display the " X10?" prompt. Enter 1 for yes.
¥ The Enter Device No. prompt for the next zone will be displayed.
¥ Press 00 and then [ ] to exit the 80 mode.
Now use 81 Zone List mode to program the 3 specific zones in Zone List 1.
Press the [ ] key to continue.
80 interactive mode we choose Output Device 01 and program the
Action (A) to be "2" (Close and stay closed). The Event we are looking for to
start the Device action is a fault, so we will program "2" in (EV). We will
use Zone List 1 for the 3 specific zones, so we will program "1" in (ZL), (and
we will program these 3 zones in 81's Zone List 1).
aux. zone (Zone Type 08), so we will program (ZT) as "08".
24-hour zone to occur; enter 1 or 2, or enter 0 for any partition.
restore of any zone, so a "0" will be programmed for the Restore of Zone
List (ZL). We will use a manual entry of User Code + [#] + [8] + Device
# to turn off. Therefore, we do not need to program a STOP event.
Press [ ] to continue.
for device 01. Press [ ] to continue.
device 01. Press [ ] to continue.