First Alert FA162C Installation Instructions Manual page 63

2-partitioned
Hide thumbs Also See for FA162C:
Table of Contents

Advertisement

[
Output Device Displays
Enter Device No.
(00 = Quit)
02
A EV ZL ZT P
STT 0 0 0 00 1
02
A EV ZL ZT P
STP – – 0 00 1
02 Device Action
No Response
02 Start Event
Not Used
02 Start:
Zn List
No List
02 Start:
Zn Typ
Not Used
Ê** Use 0 (Any) for
Partition No. (P)
entry.
***
Or at Disarming,
whichever occurs
earlier.
Programming Output Relays and Powerline Carrier Devices
While in program mode, press
Mode. This mode is used to program all output devices used in the system
(4229 or 4204 Relay modules, or Powerline Carrier devices). Refer to the
output device table for
programming output devices.
NOTE: If using Powerline Carrier Devices, the House ID of the devices must
be entered in data field *27.
After entering *80, the following prompts are displayed.
Enter the Device Number 01 or 02 for a 4229, or 01, 02, 03, or 04 for a 4204,
or 01Ð08 for Powerline Carrier devices (or 00 to end these entries). Press the
01
[ ] key to continue.
The [ ] key is used to accept an entry and advance to the next prompt. The
[#] key is used to revert back to the last question to check or change an
entry. Press [ ] to go forward again.
This screen displays a summary of the current Device START programming
(for this example, device 02 has been selected).
Press the [ ] key to continue.
This screen displays a summary of the current Device STOP programming.
Press the [ ] key to continue.
Enter the desired device action as listed below. Press the [ ] key to continue.
0 = No response
0
1 = Close for 2 seconds
Enter the event to START the relay:
0 = Not used; 2 = Fault; 1 = Alarm; 3 = Trouble
0
A zone list must be used in conjunction with an event. If a zone type/system
operation is to be used instead of an event, enter 0.
Press the [ ] key to continue.
If a zone list will be used to START the relay action, enter the zone list
number (to be programmed in field 81): 1, 2, or 3. If not used, enter 0. Press
0
the [ ] key to continue.
If a zone type or system operation will be used to START the device action,
enter the appropriate two-digit code (see table that follows). If not, enter 00.
00
Press the [ ] key to continue.
00 = Not Used
01 = Entry/Exit #1
02 = Entry/Exit #2
03 = Perimeter
20 = ArmingÐStay
21 = ArmingÐAway
22 = Disarming (Code + OFF)
31 = End of Exit Time
32 = Start of Entry Time
33 = Any Burglary Alarm
80 to enter Output Device Menu
80 on the separate programming form
*
2 = Close and Stay Closed
3 = Continuous Pulse on & off
CHOICES FOR ZONE TYPES
04 = Interior Follower
05 = Trouble Day/Alarm Night
06 = 24 Hr Silent
07 = 24 Hr Audible
CHOICES FOR SYSTEM OPERATION
36 = **At Bell Timeout***
38 = Chime
39 = Any Fire Alarm
40 = Bypassing
41 = **AC Power Failure
–63–
when
(1 sec ON, 1 sec OFF)
08 = 24 Hr Aux
09 = Fire
10 = Interior w/Delay
24 = Silent Burglary
42 = **System Battery Low
43 = Communication Failure
52 = Kissoff
58 = Duress

Advertisement