The FA162C system has the ability to record various events in a
history log (48-event capacity). The types of events to be logged can be
selected as indicated. At any time, the downloader operator can then
upload the log and view or print out all or selected categories of the log.
The log can also be cleared by the downloader operator.
The display/printout at the central station will show the date, time,
event, and description of the occurrences. The time is calculated by an
internal clock at the central station computer. Note that the time for
any events that occur prior to a system power-down or an entry into
the programming mode cannot be calculated by the central station
computer. The time will then appear on the log as ÒunknownÓ.
NOTE: System messages are logged when any non-zero selection is
made.
91 OPTION SELECTION (Audio Alarm Verification)
0 = not using AAV
1 = local lockout
2 = sounder delay
3 = local lockout and sounder delay
4 = an Audio Alarm Verification (AAV) unit is connected to the system
5 = local lockout and AAV
6 = sounder delay and AAV
7 = local lockout and sounder delay and AAV
8 = exit delay restart
For combinations of exit delay restart (option 8) with options 1-7, enter
the sum of the options desired. Ex. To select AAV and exit delay
restart, enter 12 (4+8). Press [#] first to enter 2-digit options.
UL installations: must be 0 (AAV disabled)
92 PHONE LINE MONITOR ENABLE
0 = Not used
1 = Local keypad display only when phone line is faulted
2 = Local keypad display plus keypad trouble sound when line is faulted
ÊÊÊÊEach partition turns off its own trouble sound. No automatic timeout.
3 = Same as Ò2Ó above plus Device No. 2 STARTS. If either partition is
ÊÊÊÊÊÊarmed, external sounder activates. External sounder will be turned
ÊÊoff by normal bell timeout, or by security code plus OFF from either
ÊÊpartition (it does not have to be the one that was armed).
NOTE: Option 3 may be used even if a relay unit or Powerline
carrier device is not connected to the control.
ÊÊDevice number 2 must either be programmed to be STOPPED in
ÊÊfield
80 or STOPPED by entry of security code + [#] + 8 + 2.
ÊÊPartition in 80 should be set to Ò0 Òfor STOP.
NOTE: This feature will not function properly unless the designated
earth ground terminal (25) is connected to an earth ground. If it is not,
you may get false line cut indications.
93 NUMBER OF REPORTS IN ARMED PERIOD
0 = reports limited to a total of 10
1 = unlimited number of reports
This option can be used to limit the number of messages (alarm & alarm
restore reports) sent to the central station in an armed period.
UL installations: must be 1 (unlimited reports)
94
DOWNLOAD PHONE NUMBER
Ê ÊÊÊÊ|ÊÊÊ|ÊÊÊ|ÊÊÊ|ÊÊÊ|ÊÊÊ|ÊÊÊ|ÊÊÊ|ÊÊÊ|ÊÊÊ|ÊÊÊ|ÊÊÊ|ÊÊÊ|ÊÊÊ|ÊÊÊ|ÊÊÊ
Enter up to 16 digits as follows: 0Ð9, # +11 for Ò Ó, # + 12 for Ò#Ó, # + 13
for a pause. Do not fill unused spaces. End field by entering . To clear
entries from field, press 94 .