TO PROGRAM
SYSTEM STATUS
AND RESTORE
REPORT CODES
( 59 Ð 76, &
89)
52
TEST REPORT OFFSET
0 = 24 hours after exiting program mode or download
1 = 6 hours after exiting program mode or download
2 = 12 hours after exiting program mode or download
3 = 18 hours after exiting program mode or download
This is the time to first report from programming or downloading.
53
SESCOA/RADIONICS SELECT
0 = Radionics (0Ð9, BÐF reporting)
1 = SESCOA (0Ð9 only reporting)
Select 0 for all other formats.
Report codes can be programmed using the interactive *56 Zone
Programming Mode, or codes can be entered in data fields *59-*76, *89.
The following is a set of guidelines to be used for programming report codes.
The actual report code digits that you enter depend upon the particular
installation, and should be in agreement with you and the central station
office receiving the signals. Use these guidelines to program this entire
section.
With a 3+1 or 4+1 Standard Format : Enter a code in the first box: 1Ð9, A,
B, C, D, E, or F. Enter "#+10" for A (this reports a Ò0Ó on some receivers),
"#+11" for B, "#+12" for C, "#+13" for D, "#+14" for E, "#+15" for F.
An entry of "0" in the first box will disable a report.
An entry of "0" in the second box will result in automatic advance to the
next field when programming.
With an Expanded or 4+2 Format: Enter codes in both boxes (1st and 2nd
digits) for 1Ð9, or AÐF, as described above.
An entry of "0" in the first box will disable a report.
An entry of "0" in the second box will eliminate the expanded message for
that report.
With Ademco Contact ID Reporting: Enter a digit in the first box to
enable the zone to report. Use a different digit for each zone until you have
used up available digits. If the number of zones exceeds the number of
available digits, begin with digit 1 again. This is an "enabling" code only and
is not the actual code sent to the central station office. Entries in the second
boxes will be ignored. For system status (non-alarm) codes, enter a Ò1Ó in the
first box for all the system conditions you want to send to the central station.
An entry of "0" in the first box will disable the report.