FILLING THE REFRIGERANT
§
Use the refrigerant fi lling appliances specialized for R32. Make sure that
different kinds of refrigerant will not contaminate with each other.
§
The refrigerant tank should be kept upright at the time of fi lling refrigerant.
§
Stick the label on the system after fi lling is fi nished (or have not fi nished).
§
DO NOT overfi lling.
§
After fi lling is fi nished, please do the leakage detection before test running;
Another time of leak detection should be done when it is removed.
SAFETY INSTRUCTIONS FOR TRANSPORTATION AND STORAGE
§
Please use the fl ammable gas detector to check before unload and open
the container.
§
No fi re source and smoking.
§
According to the local rules and laws.
Safety instructions when installing or moving the unit
To ensure the safety of you as well as the device, please follow the safety
instructions below.

CHECK AFTER INSTALLATION

§
Check according to the following requirement after fi nishing installation.
Items to be checked
Has the unit been installed fi rmly?
Have you done the refrigerant leakage
test?
Is heat insulation of pipline suffi cient?
Is water drained well?
Is the voltage of power supply according
to the voltage marked on the nameplate?
Is electric wiring and pipeline installed
correctly?
Is the unit grounded securely?
Possible malfunction
The unit may drop, shake or emit noise.
It may cause insuffi cient cooling or
heating capacity.
It may cause condensation and water
dripping.
It may cause condensation and water
dripping.
It may cause malfunction or damaging
the parts.
It may cause malfunction or damaging
the parts.
It may cause electric leakage.