System Operation and Functions
 Timing chart
Muting input A
(Limit switch1)
Muting input B
(Limit switch2)
Muting state
Beam state
Variable
T
1max
T
2
T
3
 Wiring diagram
+24 VDC
Power supply
0 VDC
S1, S2: Muting sensor
F3SG-R
66
User's Manual
ON
OFF
ON
OFF
80 ms max.
Enabled
Disabled
Unblocked
Blocked
ON
OSSD
OFF
Variable name
Muting input time limit value
3 s
(maximum)
Muting time limit
60 s
Maximum allowable muting
0.1 s
signal interruption
PNP output
F39-JG A-D
S1
T3 (0.1 s) max.
T3 (0.1 s) max.
T1max
T2 max.
T2 max.
Value
Maximum time difference between muting inputs A and B.
If the time difference between muting inputs A and B is larger
than this value, a muting error occurs.
The duration time of the Muting function. The Muting state is
cancelled if it continues for longer than this time limit.
Maximum duration of a signal interruption allowed in muting
inputs A and B.
+24 VDC
Power supply
0 VDC
S1, S2: Muting sensor
Description
NPN output
F39-JG A-D
S1