Self-Test; Overview; Self-Test Details - Omron F3SG RE Series User Manual

Safety light curtain
Hide thumbs Also See for F3SG RE Series:
Table of Contents

Advertisement

System Operation and Functions

2-6. Self-Test

F3SG-RA Series
F3SG-RE Series

2-6-1. Overview

The F3SG-R performs the Self-Test when power is turned ON (within 2 seconds) to check for errors.
Also, it regularly performs the Self-Test (within a response time) while operating.
This function cannot be cancelled.
Power supply
Self test
If an error is found in the Self-Test, the F3SG-R enters the Lockout state, keeps the safety output in the
OFF state, and indicates the error at the same time.

2-6-1-1. Self-Test details

The Self-Test detects such error as described below.
Emitter
• Failure of emitter unit or circuit
• CPU failure
• Memory failure
• Failure of DIP Switch*
Receiver
• Abnormal external power supply voltage
• Failure of internal power supply circuit
• Failure of receiver unit or detection circuit
• CPU failure
• Memory failure
• Failure of safety output circuit
• Disconnected or short-circuited cable
• Failure of DIP Switch*
* The Self-Test for the DIP Switch is not available for the F3SG-RE as it does not have the DIP Switch.
F3SG-R
30
User's Manual
X
X
ON
OFF
2 s max.
ON
Subsequently performs periodic test
OFF

Advertisement