Wiring/Installation
 Side Mounting
F3SG-RE30 Series
Dimension A
Dimension C1
Dimension D
Dimension P
Protective height
(C1)
0190 to 1230
1310 to 2270
2350 to 2510
*1. The number of brackets required to mount either one of emitter and receiver.
*2. Mounting an emitter or receiver with one bracket is possible for the models of protective height of 0160 to 0270. In this case, locate this bracket
at half the Dimension A (or at the center of the sensor length).
4-4-3-2. Mounting with Standard Adjustable Brackets (F39-LGA)
- Use the brackets of specified quantities and locations according to the dimensions. The other brackets than described
above may not meet the specified ratings and performance.
- When you use the sensor in a situation where the sensor is under a load, increase the number of the brackets used.
- The Standard Adjustable Bracket allows beam alignment after fixing the bracket to a wall surface. The angle adjustment
range of the Standard Adjustable Brackets is ±15°.
F3SG-R
144
User's Manual
48.6
35
Standard Adjustable
Bracket
(F39-LGA)
Standard Adjustable
Bracket
(F39-LGA)
C1
4-digit number of the type name
(Protective height)
C1-50
20
Number of Standard
Dimension F
Adjustable Brackets *1
2 *2
1000 mm max.
3
1000 mm max.
4
1000 mm max.
35
2-M5 or M6
2-M5 or M6
9.2
42.35
< Screw: M5 or M6 >
F3SG-RE14 Series
Dimension A
C2+30
4-digit number of the type name
Dimension C2
(Protective height)
Dimension D
C2-20
Dimension P
10
Protective height
Number of Standard
(C2)
Adjustable Brackets *1
0160 to 1200
2 *2
1280 to 2080
3
[ Unit : mm ]
Dimension F
1000 mm max.
1000 mm max.