Omron F3SG RE Series User Manual page 10

Safety light curtain
Hide thumbs Also See for F3SG RE Series:
Table of Contents

Advertisement

When muting error occurs with workpiece blocking the F3SG-R, there are two methods to
forcibly remove the workpiece.
1) Manual operation (with additional safety measure); or
2) Override function (Override at Normal Operation / Override upon Startup)
Only one of the methods, either 1) or 2) must be used.
If they are used at the same time, the override may be activated at an unexpected timing.
Install F3SG-R so that it is not affected by reflective surfaces. Failure to do so may hinder
detection, resulting in serious injury. For an installation distance from reflective surfaces, see 4-1-
3. Distance from Reflective Surfaces.
When using more than 1 set of F3SG-R in adjacent areas, the emitter of one F3SG-R may
interfere with the receiver of the other, causing the safety functions to stop working properly.
Install and configure them so that mutual interference does not occur.
Make sure that foreign material such as water, oil, or dust does not enter the F3SG-R or the
connector while the cap or the cover of the DIP Switch is removed.
To change the response time, calculate the safety distance based on the setting. Otherwise, the
machine may not stop before a person reaches the hazardous part, resulting in serious injury.
Do not use the sensor system with mirrors in a retro-reflective configuration as shown
below.Doing so may hinder detection. It is possible to use mirrors to alter the detection zone to a
90-degree angle.
Reflector
Reflector
Position with retro-reflection
Position with detection zone bent at 90
Perform an inspection for all F3SG-R as described in Chapter 6 Checklists. When using cascade
connections, perform inspections for every connected F3SG-R.
For wiring
When using the PNP output, connect the load between the output and 0 V line. When using the
NPN output, connect the load between the output and +24 VDC line. Connecting the load
between the output and a different power supply line from the above will result in a dangerous
condition because the operation mode of safety output is reversed to "Dark-ON".
F3SG-R
viii