System Operation and Functions
 Considerations for enabling and disabling Muting function
Setting parameters of the following functions can be saved according to the state where the Muting
function is enabled and disabled, respectively. After changing the Muting function from Enable to
Disable or from Disable to Enable, check the settings of these functions again.
Affected functions:
• External Device Monitoring (EDM)
• Start Interlock
• Restart Interlock
• Auxiliary Output
• Lamp Output
Refer to the Setting with Configuration Tool sections of the affected functions in Chapter 2 System Operation
and Functions for more information on the setting parameters.