Dimension

SeeAlso
3-4

Dimension

SeeAlso
If No was selected at step (6.), the screen for changing the OK item range
will be displayed.
0.Scn 0 =SET= Region
0.Position(No ref)
Set the range
for OK items.
X: [ 357.000: 361.000]
Y: [ 290.000: 294.000]
End
Range for OK items
automatically calculated
by the F160 based on
the coordinates.
Refer to page 19 for details on inputting values.
9.
Move the cursor to the value to be changed and specify the range for OK
items.
10. Select End.
A confirmation message will be displayed.
Add to inspection?
End
Add
4
STEP
11. Select End if there are no more conditions to be added to the inspection.
Dimension inspections inspect the relationship (distance) between two speci-
fied points to see if it is within a range.
Refer to page 3 Inspection Types.
X= 359.712
Y= 292.826
Dist= 283.155
Back
Coordinates for inspection
position for which the origin
is the upper left corner of
the screen.