Solution hose
fitting hard to
connect
Carpet not
getting clean.
Carpet too wet
Carpet browning
Solution not
flowing properly
TECHNICAL SPECIFICATIONS
POWER TYPE
ELECTRICAL: 115 V, 60 Hz, 15 Amps per power cable ((D250)
230 V, 50 Hz, 15 Amps (D250IE)
ELECTRIC VACUUM MOTOR: (1) –2/1.25 HP, 2 stage, Waterlift –150" (381cm)
SOLUTION PUMP: 250 psi, adj.
SOLUTION CAPACITY: 17 gallons (64.3ltr)
RECOVERY CAPACITY: 15 gallons (56.75ltr)
GENERAL DIMENSIONS/WEIGHT
WEIGHT: 97 lbs. ( 44 kg)
LENGTH: 20" (50.80 cm)
HEIGHT: 36" (91.44 cm)
WIDTH: 16" (40.64 cm)
POWER CABLE: 2-25' (6.35 m) (D250)
1-25' (6.35 m) (D250IE)
Corrosion on fittings
Severe soil conditions
Over saturation
Leaving carpet too wet
Too much chemical in
Solution hose connection
Faulty pump
Faulty floor tool valve
Faulty pump switch
D-250 98828 04/08/03
TROUBLESHOOTING CONT.
Clean with steel wool.
Soak in acetic acid (white vinegar).
Lubricate lightly with silicone base
lubricant.
Make several passes at right angles to
other. Use a prespray.
Adjust solution pressure to lower setting.
Make several passes without spray.
Check for loss of vac pressure.
Check label for correct solution
concentration.
Check for positive connection
Repair or replace.
Repair or replace.
Repair.
.
10