Windsor D250 (115V) Operating Instructions Manual

115v
Hide thumbs Also See for D250 (115V):

Advertisement

Quick Links

CARPET EXTRACTOR
Operating Instructions (ENG)
MODEL:
D250 (115V)
Beginning with Serial No. 1000054537
Read these instructions before operating the machine
P
98828 06/07/03

Advertisement

Table of Contents
loading

Summary of Contents for Windsor D250 (115V)

  • Page 1 CARPET EXTRACTOR Operating Instructions (ENG) MODEL: D250 (115V) Beginning with Serial No. 1000054537 Read these instructions before operating the machine 98828 06/07/03...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS MODEL DATE OF PURCHASE SERIAL NUMBER SALES REPRESENTATIVE # DEALER NAME Data Log/Table of Contents ...1 Safety Instructions ...2 Grounding Instructions...3 Operations...4 Maintenance ………………………….6-7 Troubleshooting...9-10 INSPECTION Carefully unpack and inspect your machine for shipping damage. Each unit is operated and thoroughly inspected before shipping, and any damage is the responsibility of the carrier, who should be notified immediately.
  • Page 3: Safety Instructions

    SAFETY INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONS When using an electrical appliance, basic precaution must always be followed, including the following: READ ALL INSTRUCTIONS BEFORE USING THIS MACHINE. This machine is for commercial use. WARNING: To reduce the risk of fire, electric shock, or injury: Connect to a properly grounded outlet.
  • Page 4: Grounding Instructions

    GROUNDING INSTRUCTIONS THIS PRODUCT IS FOR COMMERCIAL USE ONLY. ELECTRICAL: The amp, hertz, and voltage are listed on the data label found on each machine. voltages above or below those indicated on the data label will cause serious damage to the motors.
  • Page 5: Operations

    When possible use a Windblower (WB3) and open all windows and doors to speed carpet drying. ACCESSORIES: The D-250 can be used with the following Windsor equipment: Deluxe Hand Tool (DHT), Pile Jogger(PJ2A), Standard Floor Wands(SFW, SW, SW-PRO, PROW), & Wind Blower carpet dryer(WB3).
  • Page 6 OPERATION HEATER OPERATION The disconnect fittings on the heater will become extremely hot during operation. Allow sufficient time to cool, or run solution through the machine with the heater turned off before disconnecting the or performing any maintenance on the heater. Before disconnecting the heater, open wand valve to relieve the system of all pressure by depressing the valve trigger.
  • Page 7: Maintenance

    DAILY MAINTENANCE: (At the end of each working day) : Flush the entire system, including floor tool, hand tool, etc., with 1 to 3 gallons of clean, hot water. Vacuum out the solution tank . Rinse tank with fresh water. Periodically inspect the recovery tank and decontaminate if necessary, using a Hospital Grade Virucide or a 1-10 bleach to...
  • Page 8: Maintenance

    MAINTENANCE SERVICE SCHEDULE MAINTENANCE Check machine for cord damage Check recovery dome and gasket for damage and cleanliness Check hoses for wear, blockages, or damage Check handles, switches, and knobs for damage Check vac motor intake filter and clean Run one gallon of water through system Clean out recovery tank and check float valve to make sure it moves freely...
  • Page 9 ONLY QUALIFIED MAINTENANCE PERSONNEL ARE TO PERFORM WARNING: THE FOLLOWING REPAIRS. VACUUM MOTOR REPLACEMENT 1. Turn off all switches and unplug machine. 2. Remove recovery tank. 3. Locate the vacuum motor wires and disconnect at the connector. 4. Remove the vacuum motor. 5.
  • Page 10: Troubleshooting

    3.) 1000 hours-kit 55250752 valve assembly and o-rings. NOTE: Maintenance and repairs must be done by qualified personnel. Using non- Windsor parts to repair this machine will void the warranty. Contact an authorized Windsor dealer for complete details. TROUBLE SHOOTING CHART :...
  • Page 11: Technical Specifications

    Solution hose Corrosion on fittings fitting hard to connect Carpet not Severe soil conditions getting clean. Carpet too wet Over saturation Carpet browning Leaving carpet too wet Too much chemical in Solution not Solution hose connection flowing properly Faulty pump Faulty floor tool valve Faulty pump switch TECHNICAL SPECIFICATIONS...
  • Page 12: Wiring Diagram

    115V WIRING DIAGRAM D-250 98828 06/07/03...
  • Page 13 THIS PAGE LEFT BLANK INTENTIONALLY D-250 98828 04/08/03...
  • Page 14: Parts Lists

    RECOVERY TANK ASSEMBLY D-250 98828 06/07/03...
  • Page 15 PART NO. DESCRIPTION 05151 TUBE ASM, RECOVERY TANK 500009 LABEL, WARNING 260-64A ACCESS COVER CLEAR 6” W/RIM 70546 SCR, 8 X 3/4 PFHT/S BLK ZINC 090-12A FLOAT CAGE ASSY COMPLETE SLIP 78475 VAC STACK ASM, 17 GAL PORTABLES 320-05 VELCRO STRAPS 15-808123 DUMP VALVE 2”...
  • Page 16 SOLUTION TANK ASSEMBLY D-250 98828 06/07/03...
  • Page 17 PART NO. DESCRIPTION 85045 VAC MTR ASM, D/B SLTN 115V 2ST 39582 HOSE, VAC EXHAUST X 9” 20046 CLAMP, 2.25” WORMGEAR 880292 WIRE, 4” GRN/14 76010 X 76014 87016 WASHER, #10 LOCK EXT STAR SS 70335 SCR, 10-32 X 1/2 PHTR GRN/GRND 70813 STUD, 1/4-20 X 3.5 SS 87013...
  • Page 18: Spare Parts

    SOLUTION TANK ASSEMBLY CONT'. PART NO. DESCRIPTION 70232 SCR, 10-32 X 3/8 FHMS SS 57196 NUT, 1/2 PUSH-ON DOME CAP 040-06 WHEEL 8” BLK CENTERED HUB 010-01 AXLE ASM, LEFT 065-28 DIAMONDBACK 200 PUMP SUPPORT 040-03 CASTER SWIVEL 4” SWIVEL 290-08 SOL SCREEN (ACORN) W/RUB BASE 75349...
  • Page 19: Warranty

    The Machine Registration Card must be completed and returned immediately at the time of purchase. If proof of purchase cannot be identified, the warranty start date is 90 days after the date of sale to an authorized Windsor distributor. Parts replaced or repaired under warranty are guaranteed for the remainder of the original warranty period.
  • Page 20 If difficulty develops during the warranty period, contact the authorized Windsor agent from whom the product was purchased. Windsor Industries, Inc. may elect to require the return of components to validate a claim. Any defective part to be returned must be shipped freight prepaid to an authorized Windsor Distributor/Service Center or to the Windsor factory.

This manual is also suitable for:

Dominator d250

Table of Contents