Example of the E-mail sent for an error
The following E-mail is sent when an error has occurred.
=== Panasonic projector report(ERROR) ===
Projector Type
Serial No
----- Error information -----
H11 Intake air temp. sensor error
U84 DC OUT error
Error code :
00 00 00 00 00 00 00 20 00 00 00 01 00 00 00 00
Intake air temperature
Optics module temperature : 40 degC / 104 degF
Exhaust air temperature
Light temperature1
Light temperature2
PROJECTOR RUNTIME
POWER ON
LIGHT RUNTIME
LIGHT ON
-------- Current status ---------
MAIN VERSION
SUB VERSION
LIGHT STATUS
INPUT
----- Wired Network configuration -----
DHCP Client ON
IP address
MAC address 4C:36:4E:77:9D:CA
Wed Jan 01 00:01:09 2020
----- Memo -----
[Crestron tools] page
Set the information required to connect the Crestron control system to the projector. If you do not have Adobe
Flash
®
Player installed on your computer, or if your browser does not support Flash, the [Crestron Connected (TM)]
page will not appear. In that case, set [Control System] on this page.
Click [Detailed set up] → [Crestron tools].
1
[IP Address]
Set the IP address of the control system.
2
[IPID]
Set the IPID of the control system.
146 - ENGLISH
Chapter 5  Operations — Web control function
: PT-FRZ50
: SW1234567
:-100 degC / -148 degF
: 36 degC / 96 degF
: --- degC / --- degF
: --- degC / --- degF
1 H
5 times
1 H
5 times
0.13
0.10
LIGHT=OFF
COMPUTER1
192.168.0.100
Eco management
Network security
Crestron tools
3
[Port]
Set the port number of the control system.
4
[Submit]
Update the setting.
®