1
[COMMAND PROTECT]
Make settings for the connection authentication when using the
command control function.
[DISABLE]: Connect to the projector in non-protected mode.
Connection authentication is not performed.
[ENABLE]: Connect to the projector in protected mode.
The user name and password of the administrator account are
required for the connection authentication.
Note
f When [COMMAND PROTECT] is set to [DISABLE], connection authentication is not performed, making it vulnerable to threats on the
network. Be aware of the risks before making settings.
f For details on how to use the command control function, refer to "Control commands via LAN". ( x page 172)
[E-mail set up] page
E-mail can be sent to preset E-mail addresses (up to two addresses) periodically or when an error or problem has
occurred.
Click [Detailed set up] → [E-mail set up].
1
[ENABLE]
Select [ENABLE] to use the E-mail function.
2
[SMTP SERVER NAME]
Enter the IP address or the server name of the E-mail server
(SMTP). To enter the server name, the DNS server needs to be
set up.
3
[MAIL FROM]
Enter the E-mail address of the projector. (Up to 63 characters in
single byte)
4
[MEMO]
Enter information such as the location of the projector that notifies
the sender of the E-mail. (Up to 63 characters in single byte)
5
[MINIMUM TIME]
Change the minimum interval for the temperature warning E-mail.
The default value is 60 minutes. In this case, another E-mail will
not be sent for 60 minutes after sending the temperature warning
E-mail even if it reaches the warning temperature.
142 - ENGLISH
Chapter 5  Operations — Web control function
2
[Submit]
Updates the setting.
If you click [Submit] with [DISABLE] selected in [COMMAND
PROTECT], a confirmation screen will be displayed. Click [OK]
on the confirmation screen to update the settings.
Network security
Crestron tools
6
[INTAKE AIR TEMPERATURE]
Change the temperature setting for the temperature warning
mail. A temperature warning E-mail is sent when the temperature
exceeds this value.
1
2
1
2
3
4
5
6

Advertisement