G0623X Circuit Requirements
This machine is prewired to operate on a power
supply circuit that has a verified ground and meets
the following requirements:
Nominal Voltage ......... 208V, 220V, 230V, 240V
Cycle ..........................................................60 Hz
Phase ........................................... Single-Phase
Circuit Rating ...................................... 30 Amps
Plug/Receptacle .......................................L6-30
This machine is equipped with a power cord that
has an equipment-grounding wire and a grounding
plug. Only insert plug into a matching receptacle
(outlet) that is properly installed and grounded in
accordance with all local codes and ordinances.
DO NOT modify the provided plug!
L6-30 GROUNDED
LOCKING
RECEPTACLE
Grounding Prong
is Hooked
L6-30
LOCKING
PLUG
Current Carrying Prongs
Figure 1. Typical L6-30 plug and receptacle.
No adapter should be used with plug. If
plug does not fit available receptacle, or if
machine must be reconnected for use on a
different type of circuit, reconnection must
be performed by an electrician or qualified
service personnel, and it must comply with
all local codes and ordinances.
-14-
G0623X3 Circuit Requirements 220V
This machine is prewired to operate on a power
supply circuit that has a verified ground and meets
the following requirements:
Nominal Voltage ......... 208V, 220V, 230V, 240V
Cycle ..........................................................60 Hz
Phase .................................................... 3-Phase
Power Supply Circuit ......................... 30 Amps
Plug/Receptacle ..................................... L15-30
Cord ........"S"-Type, 4-Wire, 10 AWG, 300 VAC
The power cord and plug used on this machine
must have an equipment-grounding wire and
grounding prong. The plug must only be inserted
into a matching receptacle (outlet) that is prop-
erly installed and grounded in accordance with all
local codes and ordinances (see figure below).
GROUNDED
L15-30 RECEPTACLE
Grounding Prong
is Hooked
L15-30
PLUG
Current Carrying Prongs
Figure 2. Typical L15-30 plug and receptacle.
No adapter should be used with plug. If
plug does not fit available receptacle, or if
machine must be reconnected for use on a
different type of circuit, reconnection must
be performed by an electrician or qualified
service personnel, and it must comply with
all local codes and ordinances.