Regency Ultimate U39EX Owners & Installation Manual page 22

Freestanding gas stove
Table of Contents

Advertisement

installation
Description
Attic Insulation Shield 12"
Attic Insulation Shield
- Cold Climates 36"
Basic Horizontal Termination Kit (A)
Horizontal Termination Kit (B)
Vertical Termination Kit
High Wind Vertical Cap
High Wind Horizontal Cap
Horizontal Square Termination Cap
Vertical Termination Cap
Storm Collar
Flashing - Flat Roof
Adjustable Flashing 0/12-6/12
Adjustable Flashing 6/12-12/12
Vinyl Siding Standoff
Vinyl Siding Shield Plate
Snorkel Termination 14"
Snorkel Termination 36"
Wall Firestop
* Not available from Regency
***Olympia Ventis DV application for the following units only when using 4" x 6-5/8" vent system: B36XTE, B36XTCE, all City Series 40 models, CV72E/CB72E (power-vented
models only), G600C, G600C-1, G600EC, G800C, G800C-1, G800EC, P36, P36E, and RC500E.
FPI
946-506/P
Vent Guard (Optional) for AstroCap
**510-994
Rigid Pipe Adaptor (Must use with all rigid piping)
640-530/P
Riser Vent Terminal
**The rigid pipe adaptor is not required on the C34, C34E, U39, U39E, H15, H27, H35 & RC500E.
Note: When using Metal-Fab Sure Seal Rigid Piping - please note that the Adaptor (4DDA) must be used in conjunction with FPI Rigid Pipe Adaptor (510-994).
Offset Pipe Selection: Use this table to determine offset pipe lengths.
Pipe Length
(L)
Run (X)
0" (0mm)
4-7/8" (124mm)
6" (152mm)
8" (203mm)
9" (229mm)
10-1/8" (257mm)
12" (305mm)
12-1/4" (311mm)
24" (610mm)
20-5/8" (524mm)
36" (914mm)
29" (737mm)
48" (1219mm)
37-7/16" (951mm)
Note: Horizontal runs of vent must be level, or have a 1/4" rise for every 1 foot of run towards the termination.
Never allow the vent to run downward - this could cause high temperatures and may present a possible fire hazard.
22
|
Regency
U39EX ULTIMATE™ Freestanding Gas Stove
®
Simpson
*Selkirk
Direct Vent Pro ®
Direct Temp™
46DVA-IS
N/A
N/A
N/A
46DVA-KHA
4DT-HKA
N/A
4DT-HKB
N/A
4DT-VKC
46DVA-VCH
N/A
N/A
N/A
46DVA-HC
4DT-HHC
46DVA-VC
4DT-HVC
46DVA-SC
4DT-SC
46DVA-FF
N/A
46DVA-F6
4DT-ST14
46DVA-F12
4DT-ST36
46DVA-VSS
4DT-VS
N/A
4DT-VSP
46DVA-SNK14
N/A
N/A
N/A
46DVA-WFS
N/A
4" x 6-5/8" Venting
Rise (Y)
13-7/8" (340mm)
16-1/2" (419mm)
18-5/8" (473mm)
20-3/4" (527mm)
29-1/8" (740mm)
37-1/2" (953mm)
45-15/16" (1167mm)
*American Metal
*Metal-Fab™
*Security
Products®
Sure Seal
Secure- Vent®
Amerivent Direct
4DAIS12
4DIS
SV4RSA
4DAIS12
N/A
N/A
4DHTK2
4DHTKA
SV-SHK
4DHTK1
4DHTKB
SV-HK
4DHTK
4DHTK
SV-FK
N/A
N/A
N/A
N/A
N/A
N/A
4DHC
4DHT
SV4CHC-1
4DVC
4DVT
SV4CGV-1
4DSC
4DSC
SV4FC
N/A
N/A
N/A
4D12S
4DF
SV4STC14
4D36S
4DF-12
SV4STC36
N/A
4DVS
SV4VS
N/A
N/A
SV4VS
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
946-205
Vinyl Siding Shield for Riser Vent Terminal
946-208/P
Vent Guard (Optional) for Riser Vent Terminal
946-523/P
AstroCap Horizontal Cap
946-206
Vinyl Siding Standoff for AstroCap
For specific instructions on venting components - visit the
manufacturers website listed below.
Simpson Direct Vent Pro: www.duravent.com
Selkirk Direct-Temp: www.selkirkcorp.com
American Metal Products: www.americanmetalproducts.com
Metal-Fab Sure Seal: www.mtlfab.com
Security Secure Vent: www.securitychimneys.com
Industrial Chimney Company: www.icc-rsf.com
Olympia Ventis DV: www.olympiachimney.com
*ICC Excel
*Olympia
Direct
Ventis DV***
N/A
VDV-AIS04
TM-4AS
N/A
TM4-HTK
VDV-KW04
TM4-HTK
VDV-K04
N/A
N/A
TM-4VT
VDV-VCHW04
TM-4DHT
N/A
TM-4HT
VDV-HC04
N/A
N/A
TM-SC
VDV-SC04
N/A
N/A
TF-4FA
VDV-F0406
TF-4FB
VDV-SSO
TM-VSS
N/A
N/A
N/A
TM-4ST14
N/A
TM-4ST36
N/A
TM-4TR
VDV-FS04

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ultimate u39ex-ngUltimate u39ex-lp

Table of Contents