AGFA DX-D 40C User Manual
Hide thumbs Also See for DX-D 40C:
Table of Contents

Advertisement

DX-D 40C, DX-D 40G
6007/100
6007/200
User Manual
0290B EN 20190401 1627

Advertisement

Table of Contents
loading

Summary of Contents for AGFA DX-D 40C

  • Page 1 DX-D 40C, DX-D 40G 6007/100 6007/200 User Manual 0290B EN 20190401 1627...
  • Page 2: Table Of Contents

    | DX-D 40C, DX-D 40G | Contents Contents Legal Notice ................5 Introduction to this Manual ........... 6 Scope .................7 About the safety notices in this document ....8 Disclaimer ..............9 Introduction to the DR Detector ........... 10 Intended Use ............11...
  • Page 3 DX-D 40C, DX-D 40G | Contents | iii Additional Labeling of the System Control Unit Additional Labeling of the Mini System Control Unit ............. 46 Consulting the About box ......47 Cleaning and Disinfecting ........48 Cleaning ............49 Use of protective plastic bag ......50...
  • Page 4 | DX-D 40C, DX-D 40G | Contents Artifact in DR Detector images ......... 97 DR detector not ready for exposure ......98 Password requested when connecting to the DR Detector via the wireless network ...........99 Images are not sent to the printer or to the PACS archive ..................100...
  • Page 5: Legal Notice

    For more information on Agfa products, please visit www.agfa.com. Agfa and the Agfa rhombus are trademarks of Agfa-Gevaert N.V., Belgium or its affiliates. DX-D 40 is a trademark of Agfa NV, Belgium or one of its affiliates. All other trademarks are held by their respective owners and are used in an editorial fashion with no intention of infringement.
  • Page 6: Introduction To This Manual

    6 | DX-D 40C, DX-D 40G | Introduction to this Manual Introduction to this Manual Topics: • Scope • About the safety notices in this document • Disclaimer 0290B EN 20190401 1627...
  • Page 7: Scope

    DX-D 40C, DX-D 40G | Introduction to this Manual | 7 Scope This manual contains information for the safe and effective operation of the DX-D 40C and DX-D 40G wireless DR Detectors and peripheral equipment, further referred to as the DR Detector.
  • Page 8: About The Safety Notices In This Document

    8 | DX-D 40C, DX-D 40G | Introduction to this Manual About the safety notices in this document The following samples show how warnings, cautions, instructions and notes appear in this document. The text explains their intended use. DANGER: A danger safety notice indicates a hazardous situation of direct, immediate danger for a potential serious injury to a user, engineer, patient or any other person.
  • Page 9: Disclaimer

    DX-D 40C, DX-D 40G | Introduction to this Manual | 9 Disclaimer Agfa assumes no liability for use of this document if any unauthorized changes to the content or format have been made. Every care has been taken to ensure the accuracy of the information in this document.
  • Page 10: Introduction To The Dr Detector

    10 | DX-D 40C, DX-D 40G | Introduction to the DR Detector Introduction to the DR Detector Topics: • Intended Use • Indications for Use • Intended User • Configuration • Equipment Classification • Options and Accessories • Operation Controls •...
  • Page 11: Intended Use

    DX-D 40C, DX-D 40G | Introduction to the DR Detector | 11 Intended Use The DR Detector is a wired and wireless radiographic digital X-ray imaging device commonly referred to as flat panel detector. It is designed for all general radiography applications. The DR Detector will be used in a radiological environment by qualified staff to capture the X-ray images and send these images to the imaging processing software.
  • Page 12: Configuration

    12 | DX-D 40C, DX-D 40G | Introduction to the DR Detector Configuration The DR Detector is a component that can be integrated in an X-ray system and that communicates to a workstation. Multiple DR Detectors can communicate to a single workstation. A DR Detector can be shared between multiple workstations.
  • Page 13 DX-D 40C, DX-D 40G | Introduction to the DR Detector | 13 DR Detector DR Detector connector cable (wired configuration) System Control Unit Workstation Figure 2: DR Detector configuration (wired) 0290B EN 20190401 1627...
  • Page 14 14 | DX-D 40C, DX-D 40G | Introduction to the DR Detector DR Detector DR Detector battery DR Detector battery charger X-ray generator System Control Unit (including a wireless access point) Workstation Figure 3: DR Detector configuration with X-ray generator synchronization...
  • Page 15: Equipment Classification

    DX-D 40C, DX-D 40G | Introduction to the DR Detector | 15 Equipment Classification Per EN/IEC60601-1, Medical Electrical Equipment, General Requirements for Safety, the DR Detector, including the battery pack, is classified as following. Type of protec- Internally powered (wireless configuration)
  • Page 16: Options And Accessories

    16 | DX-D 40C, DX-D 40G | Introduction to the DR Detector Options and Accessories • DR Detector battery • DR Detector battery charger • Handle with screws • Click-on grid The delivery contains a set of labels. When using multiple DR Detector, on the labels a nickname is written to identify the DR Detector.
  • Page 17: Anti-Scatter Grids

    DX-D 40C, DX-D 40G | Introduction to the DR Detector | 17 Anti-scatter grids Anti-scatter grids are used to reduce scattered radiation and improve image quality. Grids are available as an option. Refer to the Agfa website for specifications on the anti-scatter grids that have been found compatible with the system and the DR Detectors.
  • Page 18: Dr Detector Cable

    18 | DX-D 40C, DX-D 40G | Introduction to the DR Detector DR Detector cable The DR Detector cable connects the DR Detector to the System Control Unit. The DR Detector cable can be used for two different functions. Which of two functions is enabled, is selected at installation.
  • Page 19: Operation Controls

    DX-D 40C, DX-D 40G | Introduction to the DR Detector | 19 Operation Controls Topics: • DX-D 40C, DX-D 40G • DR Detector Battery Charger • DR Detector Dual Battery Charger • System Control Unit • DR Detector Switch on the NX Workstation...
  • Page 20: Dx-D 40C, Dx-D 40G

    20 | DX-D 40C, DX-D 40G | Introduction to the DR Detector DX-D 40C, DX-D 40G DR Detector battery lock lever Unlock the battery. DR Detector battery Supplies power to the detector during wireless communication. Antenna of the wireless network adapter Operation in wireless configuration.
  • Page 21: Dr Detector Battery Charger

    DX-D 40C, DX-D 40G | Introduction to the DR Detector | 21 DR Detector Battery Charger The battery charger has three slots to insert a battery. Battery status indicator light • Orange to indicate that the battery is charging. • Green to indicate that the battery is fully charged.
  • Page 22: Dr Detector Dual Battery Charger

    22 | DX-D 40C, DX-D 40G | Introduction to the DR Detector DR Detector Dual Battery Charger The dus battery charger is available depending on the configuration of the system. The battery charger has two slots to insert two different battery models.
  • Page 23: System Control Unit

    DX-D 40C, DX-D 40G | Introduction to the DR Detector | 23 System Control Unit The System Control Unit is connected to the DR Detector via wireless network or via the DR Detector cable. The System Control Unit is connected to the X-ray generator to synchronize the exposure, in a configuration with X-ray generator synchronization.
  • Page 24: Dr Detector Switch On The Nx Workstation

    24 | DX-D 40C, DX-D 40G | Introduction to the DR Detector DR Detector Switch on the NX Workstation The DR Detector Switch is available in the title bar of the NX application. The DR Detector Switch shows which DR Detector is active and shows its status.
  • Page 25 DX-D 40C, DX-D 40G | Introduction to the DR Detector | 25 Meaning DR Detec- DR Detector is DR Detector is DR Detector is tor is ready initializing for off or discon- inactive (no for expo- exposure nected or in...
  • Page 26: System Documentation

    26 | DX-D 40C, DX-D 40G | Introduction to the DR Detector System Documentation The documentation consists of a User manual (this document) and related documentation: • NX User Manual (4420). • NX Key User Manual (4421). • NX Getting Started Sheets (4424).
  • Page 27: Training

    DX-D 40C, DX-D 40G | Introduction to the DR Detector | 27 Training The user must have received adequate training on the safe and effective use of the system before attempting to work with it. Training requirements may vary from country to country. The user must make sure that training is received in accordance with local laws or regulations that have the force of law.
  • Page 28: Product Complaints

    28 | DX-D 40C, DX-D 40G | Introduction to the DR Detector Product Complaints Any health care professional (for example a customer or a user) who has any complaints or has experienced any dissatisfaction with the quality, durability, reliability, safety, effectiveness, or performance of this product must notify Agfa.
  • Page 29: Compatibility

    DX-D 40C, DX-D 40G | Introduction to the DR Detector | 29 Compatibility The system must only be used in combination with other equipment or components if these are expressly recognized by Agfa as compatible. A list of such equipment and components is available from Agfa service on request.
  • Page 30: Compliance

    30 | DX-D 40C, DX-D 40G | Introduction to the DR Detector Compliance Topics: • General • Safety • Electromagnetic Compatibility • Radio Frequency 0290B EN 20190401 1627...
  • Page 31: General

    DX-D 40C, DX-D 40G | Introduction to the DR Detector | 31 General • The product has been designed in accordance with the MEDDEV Guidelines relating to the application of Medical Devices and have been tested as part of the conformity assessment procedures required by 93/42/EEC Medical Device Directive (European Council Directive 93/42/EEC on Medical Devices).
  • Page 32: Radio Frequency

    32 | DX-D 40C, DX-D 40G | Introduction to the DR Detector Radio Frequency Declaration of conformity U.S.A. FCC Part 15.107(b) / Part 15.109(b) FCC Part 15 Subpart E 15.407 FCC Part 15 Subpart C 15.247 European Un- ETSI EN 301 489-1 V1.8.1 (EMC) ion (and EEA) ETSI EN 301 489-17 V2.1.1 (EMC)
  • Page 33 DX-D 40C, DX-D 40G | Introduction to the DR Detector | 33 incorporated in the device in the following Member States: Belgium (BE), Bulgaria (BG), Czech Republic (CZ), Denmark (DK), Germany (DE), Estonia (EE), Ireland (IE), Greece (EL), Spain (ES), France (FR), Croatia (HR), Italy...
  • Page 34: Connectivity

    34 | DX-D 40C, DX-D 40G | Introduction to the DR Detector Connectivity Topics: • Wireless Communication • Wired communication 0290B EN 20190401 1627...
  • Page 35: Wireless Communication

    DX-D 40C, DX-D 40G | Introduction to the DR Detector | 35 Wireless Communication Wireless communication is established between the internal wireless module of the DR Detector and the NX workstation via the wireless access point. The DR Detector is compliant with IEEE 802.11n (2.4 GHz/5 GHz). The available frequency band varies depending on local radio laws and system requirements.
  • Page 36: Wired Communication

    36 | DX-D 40C, DX-D 40G | Introduction to the DR Detector Wired communication The use of accessories and cables other than those specified or sold by the manufacturer as replacement parts, may result in increased radiation emissions or decreased stability of the equipment.
  • Page 37: Installation

    DX-D 40C, DX-D 40G | Introduction to the DR Detector | 37 Installation Installation and configuration is performed by an Agfa trained and authorized service engineer. Contact your local support organization for more information. On a configuration with multiple DR Detectors of the same type, it is required to apply labeling to the DR Detector containing a unique nickname for each DR Detector.
  • Page 38 38 | DX-D 40C, DX-D 40G | Introduction to the DR Detector Note: This product may malfunction due to electromagnetic waves caused by portable personal telephones, transceivers, radio- controlled toys, etc. Be sure to avoid having objects such as these, which affect this product, brought near the product.
  • Page 39: Messages

    DX-D 40C, DX-D 40G | Introduction to the DR Detector | 39 Messages Under certain conditions the DR Detector shows a dialog box containing a message in the middle of the screen of the NX workstation. This message informs the user that either a problem has occurred or that a requested action cannot be performed.
  • Page 40: Labels

    40 | DX-D 40C, DX-D 40G | Introduction to the DR Detector Labels Symbol Explanation On (power: connection to the mains) On (power: connection to the mains) for part of the equipment Off (power: disconnection from the mains) Off (power: disconnection from the mains) for part of...
  • Page 41 DX-D 40C, DX-D 40G | Introduction to the DR Detector | 41 Symbol Explanation Manufacturer Date of manufacture Serial number This mark shows compliance of the equipment with Di- rective 93/42/EEC (for European Union). This mark shows compliance with both Canadian and U.S.
  • Page 42 42 | DX-D 40C, DX-D 40G | Introduction to the DR Detector Symbol Explanation Dangerous voltage General Mandatory action. Topics: • Additional Labeling of the DR Detector • Additional Labeling of the DR Detector battery • Additional Labeling of the DR Detector battery charger •...
  • Page 43: Additional Labeling Of The Dr Detector

    DX-D 40C, DX-D 40G | Introduction to the DR Detector | 43 Additional Labeling of the DR Detector Type label on the back side of the DR Detec- tor. DR Detector identification label Label Meaning Writable label to identify and dedicate a DR Detector to an X- ray system bucky.
  • Page 44: Additional Labeling Of The Dr Detector Battery Charger

    44 | DX-D 40C, DX-D 40G | Introduction to the DR Detector Additional Labeling of the DR Detector battery charger Type label on the bottom side of the battery charger. 0290B EN 20190401 1627...
  • Page 45: Additional Labeling Of The System Control Unit

    DX-D 40C, DX-D 40G | Introduction to the DR Detector | 45 Additional Labeling of the System Control Unit Type label on the bottom side of the System Con- trol Unit. 0290B EN 20190401 1627...
  • Page 46: Additional Labeling Of The Mini System Control Unit

    46 | DX-D 40C, DX-D 40G | Introduction to the DR Detector Additional Labeling of the Mini System Control Unit Type label on the bottom side of the Mini Sys- tem Control Unit. 0290B EN 20190401 1627...
  • Page 47: Consulting The About Box

    DX-D 40C, DX-D 40G | Introduction to the DR Detector | 47 Consulting the About box 1. Click About the solution in the Tools section of the Main Menu window on the NX workstation. Figure 9: Main Menu window. This will open the About box showing the current release and version details of the DR Retrofit solution and the XRDI software.
  • Page 48: Cleaning And Disinfecting

    48 | DX-D 40C, DX-D 40G | Introduction to the DR Detector Cleaning and Disinfecting All appropriate policies and procedures should be followed to avoid contamination of the staff, patients and equipment. All existing universal precautions should be extended to avoid potential contaminations and to avoid patients coming into (close) contact with the device.
  • Page 49: Cleaning

    DX-D 40C, DX-D 40G | Introduction to the DR Detector | 49 Cleaning To clean the exterior of the equipment: 1. Stop the system WARNING: When the equipment is going to be cleaned, be sure to turn OFF the power of each device, and to unplug the power cord from the AC outlet.
  • Page 50: Use Of Protective Plastic Bag

    50 | DX-D 40C, DX-D 40G | Introduction to the DR Detector Use of protective plastic bag WARNING: Liquids ingressing the DR Detector may cause malfunction and contamination. If there is a chance that the detector comes in contact with liquids (bodily fluids, disinfectants,...), the DR Detector must be wrapped in a protective...
  • Page 51: Disinfecting

    DX-D 40C, DX-D 40G | Introduction to the DR Detector | 51 Disinfecting To disinfect the device, use only disinfectants and disinfection methods that are approved by Agfa and that correspond to the national regulation and guidelines as well as explosion protection. If you plan to use other disinfectants, approval of Agfa is needed before use, as most disinfectants can damage the device.
  • Page 52: Approved Disinfectants

    52 | DX-D 40C, DX-D 40G | Introduction to the DR Detector Approved disinfectants Refer to the Agfa website for specifications on the disinfectants that have been found compatible with the cover material of the device and can be used on the outer surface of the device.
  • Page 53: Safety Directions For Disinfection

    DX-D 40C, DX-D 40G | Introduction to the DR Detector | 53 Safety directions for disinfection WARNING: When the equipment is going to be cleaned, be sure to turn OFF the power of each device, and to unplug the power cord from the AC outlet.
  • Page 54: Maintenance

    54 | DX-D 40C, DX-D 40G | Introduction to the DR Detector Maintenance Always consult the Agfa Service documentation and an Agfa trained and authorized service engineer for complete maintenance schedules. In order to ensure that the equipment is used safely and normally, be sure to inspect the equipment before use.
  • Page 55: Daily Inspection

    DX-D 40C, DX-D 40G | Introduction to the DR Detector | 55 Daily inspection WARNING: For safety reasons, be sure to turn OFF the power to each piece of equipment before performing the following. Otherwise, an electric shock may result.
  • Page 56: Half-Yearly Inspection

    56 | DX-D 40C, DX-D 40G | Introduction to the DR Detector Half-yearly inspection To indicate when the half-yearly calibration is due, a message is displayed on the NX workstation. Perform calibration half-yearly or when exposure conditions have changed significantly. For details, refer to the DX-D DR Detector Calibration Key User Manual (0134).
  • Page 57: Regular Inspection And Maintenance

    DX-D 40C, DX-D 40G | Introduction to the DR Detector | 57 Regular Inspection and Maintenance In order to ensure the safety of patients, operating personnel and third parties, and to maintain the performance and reliability of the equipment, be sure to perform regular inspection at least once a year.
  • Page 58: Replacement Parts Support

    58 | DX-D 40C, DX-D 40G | Introduction to the DR Detector Replacement Parts Support Parts required to maintain the functioning of the product will be stocked for seven years after discontinuance of production, to allow for repair. 0290B EN 20190401 1627...
  • Page 59: Repair

    DX-D 40C, DX-D 40G | Introduction to the DR Detector | 59 Repair The product can only be repaired in the factory. 0290B EN 20190401 1627...
  • Page 60: Patient Data Security

    60 | DX-D 40C, DX-D 40G | Introduction to the DR Detector Patient data security The user must ensure that the patients’ legal requirements are met and that the security of the patient data is guarded. The user must define who can access patient data in which situations.
  • Page 61: Environmental Protection

    DX-D 40C, DX-D 40G | Introduction to the DR Detector | 61 Environmental Protection Disposal of this product in an unlawful manner may have a negative impact on health and on the environment. Therefore, when disposing of this product, be absolutely sure to follow the procedure which is in conformity with the laws and regulations applicable in your area.
  • Page 62: Safety Directions

    62 | DX-D 40C, DX-D 40G | Introduction to the DR Detector Safety Directions WARNING: Safety is only guaranteed when an Agfa certified field service engineer has installed the product. WARNING: Improper changes, additions, maintenance or repair of the system can lead to personal injury, electrical shock and damage to the equipment.
  • Page 63 DX-D 40C, DX-D 40G | Introduction to the DR Detector | 63 staples or clips fall into the equipment, or if liquid is spilled, it may result in fire or electric shock. WARNING: Do not hit or drop the equipment. The equipment may be damaged if it receives a strong jolt, which may result in fire or electric shock if the equipment is used without being repaired.
  • Page 64 64 | DX-D 40C, DX-D 40G | Introduction to the DR Detector CAUTION: Handle the equipment carefully. Do not submerge the equipment in water. The internal image sensor may be damaged if something hits against it, or if it is dropped, or receives a strong jolt.
  • Page 65 DX-D 40C, DX-D 40G | Introduction to the DR Detector | 65 2. Perform a calibration of the DR Detector. For instructions, refer to the DX-D DR Detector Calibration Key User Manual (document 0134). 3. Perform a flat field exposure and check the image for visible artifacts.
  • Page 66: Dr Detector Battery

    66 | DX-D 40C, DX-D 40G | Introduction to the DR Detector DR Detector Battery Safety Directions WARNING: Do not use any charger other than that specifically provided for use with the equipment. The battery is used with the DR Detector. Do not use them in other combinations.
  • Page 67 DX-D 40C, DX-D 40G | Introduction to the DR Detector | 67 Do not let the battery pack and battery charger come into contact with water or other liquids and do not allow them to get wet. Do not clean with substances containing organic solvents such as alcohol, benzene, thinner, or other chemicals.
  • Page 68: Safety Directions For The Power Supply

    68 | DX-D 40C, DX-D 40G | Introduction to the DR Detector Safety directions for the power supply WARNING: Do not operate the equipment using any type of power supply other than the one indicated on the rating label. Otherwise, it may result in fire or electric shock.
  • Page 69 DX-D 40C, DX-D 40G | Introduction to the DR Detector | 69 WARNING: Be sure to hold the plug or connector to unplug the power cord. If you pull the power cord, the core wire may be damaged, resulting in fire or electric shock.
  • Page 70: Safety Directions For The System Control Unit

    70 | DX-D 40C, DX-D 40G | Introduction to the DR Detector Safety directions for the System Control Unit WARNING: Do not block the ventilation ports to prevent overheating. Overheating can cause system malfunction and damages. WARNING: Ensure continuous power supply to the system, with voltage and current according to the product specifications.
  • Page 71: Getting Started

    DX-D 40C, DX-D 40G | Getting started | 71 Getting started Topics: • Starting the DR Detector • Basic Workflow DR Detector • Guidelines for Pediatric Applications • Stopping the DR Detector • Automatic exposure detection • Attaching the Handle Unit without Grid •...
  • Page 72: Starting The Dr Detector

    Starting the DR Detector CAUTION: Do not use the battery pack as a power source for equipment other than DX-D 40C or DX-D 40G detectors. Be sure to use only the dedicated battery pack for the DX-D 40C or DX-D 40G detector.
  • Page 73 DX-D 40C, DX-D 40G | Getting started | 73 4. Turn on the detector. Note: Before operating the detector, start up the NX workstation. Press and hold the power button for 1 second. Figure 14: Power button After startup the green status indicator is lit, indicating the power status.
  • Page 74: Basic Workflow Dr Detector

    74 | DX-D 40C, DX-D 40G | Getting started Basic Workflow DR Detector Topics: • Step 1: retrieve the patient info • Step 2: select the exposure • Step 3: prepare the exposure • Step 4: check the exposure settings •...
  • Page 75: Step 1: Retrieve The Patient Info

    DX-D 40C, DX-D 40G | Getting started | 75 Step 1: retrieve the patient info At the NX workstation: 1. When a new patient comes in, define the patient info for the exam. 2. Start the exam. Step 2: select the exposure 1.
  • Page 76: Step 3: Prepare The Exposure

    76 | DX-D 40C, DX-D 40G | Getting started Step 3: prepare the exposure In the examination room: 1. Position the DR Detector. When using the bucky, check that the identification labels on the DR Detector and on the bucky match. Do not use a DR Detector that is dedicated to another bucky.
  • Page 77: Step 4: Check The Exposure Settings

    DX-D 40C, DX-D 40G | Getting started | 77 Step 4: check the exposure settings On the DR Detector Switch: 1. Check if the DR Detector Switch displays the name of the DR Detector that's being used 2. If a wrong DR Detector is displayed, select the right DR Detector by clicking the drop down arrow on the DR Detector Switch.
  • Page 78: Step 5: Execute The Exposure

    78 | DX-D 40C, DX-D 40G | Getting started Step 5: execute the exposure Press the exposure button to execute the exposure. Make sure the generator is ready for exposure before you press the exposure button. WARNING: The radiation indicator on the control console lights up during exposure release.
  • Page 79: Step 6: Perform A Quality Control

    DX-D 40C, DX-D 40G | Getting started | 79 Step 6: perform a quality control At the NX workstation: 1. Select the image on which quality control is to be performed. 2. Prepare the image for diagnosis by using e.g. L/R markers or annotations.
  • Page 80: Positioning The Dr Detector

    80 | DX-D 40C, DX-D 40G | Getting started Positioning the DR Detector WARNING: Because the equipment cable is long, take care that cables do not become tangled during use. Also, be careful not to get your feet caught in the cable. It may cause a malfunction of the equipment or injury to the user from tripping over the cable.
  • Page 81 DX-D 40C, DX-D 40G | Getting started | 81 Table 1: Skull AP portrait Figure 16: Skull AP portrait 1. Detector orientation (Portrait) 2. Patient orientation (AP) 3. Result on monitor Table 2: Chest PA Landscape Figure 17: Chest PA landscape 1.
  • Page 82 82 | DX-D 40C, DX-D 40G | Getting started Table with bucky, landscape Note: NX is configured for a specific patient orientation, either head left (default) or head right. Table 4: Wallstand bucky Wallstand with left loading bucky, portrait Wallstand with left loading bucky, land-...
  • Page 83: Guidelines For Pediatric Applications

    DX-D 40C, DX-D 40G | Getting started | 83 Guidelines for Pediatric Applications CAUTION: Children are more radiosensitive than adults. Adopting the Image Gently campaign guidelines and reducing dose for radiographic procedures while maintaining acceptable clinical image quality will benefit patients.
  • Page 84 84 | DX-D 40C, DX-D 40G | Getting started • Avoid multiple scans and use alternative diagnostic studies (such as ultrasound or MRI) when possible. 0290B EN 20190401 1627...
  • Page 85: Stopping The Dr Detector

    DX-D 40C, DX-D 40G | Getting started | 85 Stopping the DR Detector To stop the DR Detector: 1. Turn off the detector. Press and hold the power button (approx. 3 seconds). All the status indicator lights are off. 2. While holding down the battery pack, slide the lock levers toward (unlock) (1), put your fingers on the battery edge that lifts up, and then pull the edge to remove the battery pack (2).
  • Page 86: Automatic Exposure Detection

    86 | DX-D 40C, DX-D 40G | Getting started Automatic exposure detection The DR detector detects X-ray exposure to automatically perform the image acquisition. Before performing the exposure, the DR detector must be ready. Check the status of the DR detector in the DR Detector Switch.
  • Page 87: Attaching The Handle Unit Without Grid

    DX-D 40C, DX-D 40G | Getting started | 87 Attaching the Handle Unit without Grid To attach the handle unit for making exposures without using the grid 1. Lay down the handle unit on a flat surface. 2. Lay the DR Detector in the handle unit, bottom edge first, with the tube side facing up (1).
  • Page 88: Attaching The Handle Unit With Grid

    88 | DX-D 40C, DX-D 40G | Getting started Attaching the Handle Unit with Grid To attach the handle unit for making exposures using the grid 1. Lay down the grid on a flat surface. 2. Lay the DR Detector in the grid, bottom edge first, with the tube side facing down (1).
  • Page 89: Advanced Operating

    DX-D 40C, DX-D 40G | Advanced Operating | 89 Advanced Operating Topics: • Detector Status Indicators • Charging a battery • Registering the DR Detector on another NX Workstation • Using the Windows wifi settings to switch between the wireless DR...
  • Page 90: Detector Status Indicators

    90 | DX-D 40C, DX-D 40G | Advanced Operating Detector Status Indicators Table 5: Detector status Status Power indica- Status indica- Data indicator Power on Detector ready Data communication on- going Wireless data communica- tion setup ongoing Power off Note: When two or more status indicator lights are flashing, an error has occurred.
  • Page 91: Charging A Battery

    DX-D 40C, DX-D 40G | Advanced Operating | 91 Charging a battery To charge a battery using the battery charger: 1. Connect the power supply to the mains power and to the power socket of the battery charger. 2. Insert the battery in an empty slot of the battery charger.
  • Page 92: Registering The Dr Detector On Another Nx Workstation

    Note: On a PC without NX software, the VDI Panel Sharing Tool may not be set up to start automatically. To start it manually, in the Start menu, select All programs > Agfa > Start VDI Panel Sharing Tool. To register the DR Detector and make a connection to another X-ray room: 1.
  • Page 93 DX-D 40C, DX-D 40G | Advanced Operating | 93 The DR Detector is set up to make connection to the selected NX workstation. Related Links DR Detector cable on page 18 Configuration on page 12 0290B EN 20190401 1627...
  • Page 94: Using The Windows Wifi Settings To Switch Between The Wireless Dr Detector And The Wireless Hospital Network

    94 | DX-D 40C, DX-D 40G | Advanced Operating Using the Windows wifi settings to switch between the Hospital Network wireless DR detector and the wireless hospital network The NX Workstation can be configured to connect to a wireless DR Detector as well as to a wireless hospital network.
  • Page 95 DX-D 40C, DX-D 40G | Advanced Operating | 95 • To connect to the hospital network, select name of the hospital network. Do not enable the option to connect automatically to the hospital network. The NX Workstation is connected to the hospital network to retrieve data from the RIS or to print or archive images.
  • Page 96: Problem Solving

    96 | DX-D 40C, DX-D 40G | Problem solving Problem solving Topics: • Artifact in DR Detector images • DR detector not ready for exposure • Password requested when connecting to the DR Detector via the wireless network • Images are not sent to the printer or to the PACS archive •...
  • Page 97: Artifact In Dr Detector Images

    DX-D 40C, DX-D 40G | Problem solving | 97 Artifact in DR Detector images Details An artifact is visible in the images produced by a DR Detector. Cause Exposure conditions have changed significantly since latest calibration. Brief Solution Perform calibration of the DR Detector.
  • Page 98: Dr Detector Not Ready For Exposure

    98 | DX-D 40C, DX-D 40G | Problem solving DR detector not ready for exposure Details The DR detector is turned on. The DR Detector Status icon on the DR Detector Switch is not green. Cause (only if the DR Detector is shared between multiple NX...
  • Page 99: Password Requested When Connecting To The Dr Detector Via The Wireless Network

    DX-D 40C, DX-D 40G | Problem solving | 99 Password requested when connecting to the DR Detector via the wireless network Details When connecting to the DR Detector by selecting it from the list of available wireless networks, a password is requested.
  • Page 100: Images Are Not Sent To The Printer Or To The Pacs Archive

    100 | DX-D 40C, DX-D 40G | Problem solving Images are not sent to the printer or to the PACS archive Details The exam is closed, but the images are not sent to the printer or to the PACS archive.
  • Page 101: Identifying Problems

    DX-D 40C, DX-D 40G | Problem solving | 101 Identifying problems Please refer to the details of following symptoms or error messages. If the problem persists, turn off the detector and consult your sales representative or local dealer. WARNING: Improper changes, additions, maintenance or repair of the system can lead to personal injury, electrical shock and damage to the equipment.
  • Page 102 102 | DX-D 40C, DX-D 40G | Problem solving Symptom Cause Remedy Check if the wireless network communication is stable. All status indica- A hardware error has Turn off the DR Detector and tors are flashing. occurred. turn it on again.
  • Page 103: Technical Data

    DX-D 40C, DX-D 40G | Technical Data | 103 Technical Data Topics: • DX-D 40C, DX-D 40G • DX-D 40C, DX-D 40G Battery • DX-D 40C, DX-D 40G Battery Charger • DR Detector Dual Battery Charger • System Control Unit •...
  • Page 104: Dx-D 40C, Dx-D 40G

    104 | DX-D 40C, DX-D 40G | Technical Data DX-D 40C, DX-D 40G Commercial name DX-D 40C, DX-D 40G Electrical connection DR Detector Rated power supply DC +24 V, Max. 0.5 A (powered by battery pack) Power consumption max. 12 W Wireless connection IEEE 802.11a/b/g/n (2.4 GHz/5 GHz)
  • Page 105 DX-D 40C, DX-D 40G | Technical Data | 105 Vibration tolerance 2 G during normal operation 5G during storage and transport Shock tolerance 20 G during normal operation 30 G during storage and transport Drop limit 700 mm (once) Image acquisition time 6.5 s...
  • Page 106: Dx-D 40C, Dx-D 40G Battery

    106 | DX-D 40C, DX-D 40G | Technical Data DX-D 40C, DX-D 40G Battery Type of product Rechargeable lithium ion battery pack Part number FXRB-01A Dimensions Dimensions (length x width x 144.4 mm x 143.4 mm x 7.0 mm height)
  • Page 107: Dx-D 40C, Dx-D 40G Battery Charger

    DX-D 40C, DX-D 40G | Technical Data | 107 DX-D 40C, DX-D 40G Battery Charger Type of product Lithium ion battery pack charger Part number FXRC-01A Charging time 2 hours Simultaneous charging 3 batteries Dimensions Dimensions (width x height x depth) 192.0 mm x 167.5 mm x 223.4 mm...
  • Page 108: Dr Detector Dual Battery Charger

    108 | DX-D 40C, DX-D 40G | Technical Data DR Detector Dual Battery Charger Type of product Lithium ion battery pack charger Part number FXRC-03A Charging time 3 hours Simultaneous charging 2 batteries Dimensions Dimensions (width x height x depth) 190.0 mm x 163.6 mm x 34.0 mm Weight 0.5 kg...
  • Page 109: System Control Unit

    DX-D 40C, DX-D 40G | Technical Data | 109 System Control Unit System Control Unit Type 6007/300 Rated power supply AC100 to 240V, 50/60 ㎐, Max. 2.0-0.8A (input) Rated power supply DC +24V 3.25A, 78W (output) Wireless connection IEEE 802.11n (2.4 GHz/5 GHz)
  • Page 110: Mini System Control Unit

    110 | DX-D 40C, DX-D 40G | Technical Data Mini System Control Unit Mini System Control Unit Type 6007/301 Rated power supply DC +24V 2A max (input) Wireless connection IEEE 802.11n (2.4 GHz/5 GHz) Dimensions (width x height x 210 mm x 170 mm x 45 mm...
  • Page 111: Remarks For Hf-Emission And Immunity

    DX-D 40C, DX-D 40G | Remarks for HF-emission and immunity | 111 Remarks for HF-emission and immunity Topics: • EMC (Electromagnetic Compatibility) Statements • Electromagnetic emissions • Electromagnetic immunity • For U.S.A. 0290B EN 20190401 1627...
  • Page 112: Emc (Electromagnetic Compatibility) Statements

    112 | DX-D 40C, DX-D 40G | Remarks for HF-emission and immunity EMC (Electromagnetic Compatibility) Statements WARNING: This device has been tested for EMI/EMC compliance, but interference can still occur in an electromagnetically noisy location. Attempt to maintain a suitable distance between electrical devices to prevent malfunction.
  • Page 113: Electromagnetic Emissions

    DX-D 40C, DX-D 40G | Remarks for HF-emission and immunity | 113 Electromagnetic emissions This device has been tested for a normal hospital environment as described below. The user of the device should ensure that it is used in such an environment.
  • Page 114: Electromagnetic Immunity

    114 | DX-D 40C, DX-D 40G | Remarks for HF-emission and immunity Electromagnetic immunity This DR Detector is intended for operation in the electromagnetic environment given below. The user of the DR Detector should ensure that it is used in such an environment.
  • Page 115 DX-D 40C, DX-D 40G | Remarks for HF-emission and immunity | 115 Magnetic field 30 A/m 30 A/m Magnetic field at the net- at the supply work frequency should frequency correspond to the typical (50/60 Hz) in values as they are in a...
  • Page 116 116 | DX-D 40C, DX-D 40G | Remarks for HF-emission and immunity WARNING: The field strength of stationary transmitters, such as base stations of radio telephones, mobile broadcasts for rural areas, amateur stations, and AM and FM radio transmitters, cannot be precisely predetermined theoretically. An investi-...
  • Page 117: For U.s.a

    DX-D 40C, DX-D 40G | Remarks for HF-emission and immunity | 117 For U.S.A. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: • This device may not cause harmful interference.

This manual is also suitable for:

Dx-d 40g6007/1006007/200

Table of Contents