Siemens SIMOTICS S-1FK2 Operating Instructions Manual page 51

Hide thumbs Also See for SIMOTICS S-1FK2:
Table of Contents

Advertisement

Motor type
Holding tor‐
que
at 120 °C
M
/ Nm
4
For spring-loaded brake
1F☐2☐03
1.3
1F☐2☐04
3.3
For permanent-magnet brake
1F☐2☐05
8
1F☐2106
16
1F☐2206
13
1F☐2☐08-3
19
1F☐2☐08-4
32
1F☐2☐08-5
1F☐2☐10-3
32
1F☐2☐10-4
55
1F☐2☐10-5
1)
Measured with varistor for a rated holding brake voltage of 24 V DC.
Maximum three EMERGENCY STOP operations in sequence with a maximum of 25% total operating energy
2)
Note
If the brake is switched in two stages (two clicks), the first switching point is decisive for opening
and the second for closing.
I
t
t
0
t
c1
A
Figure 3-9
Holding torque M
SIMOTICS S-1FK2 synchronous motors for SINAMICS S120
Operating Instructions, 02/2022, A5E46089564B AD
Dyn. braking
Rated cur‐
torque
rent
M
/ Nm
I
1m
supp
1.3
0.4
3.3
0.5
5
0.6
9
0.7
6.5
0.7
12
0.8
17
0.9
17
0.9
26
1.0
Current
Time
Opening time
Closing time
Brake opened
Terminology (time) for holding operation
4
Opening
time
1)
/ A
t / ms
90
110
90
100
100
100
200
200
220
Mounting and options
3.8 Holding brake
Closing
Maximum
time
permissible
1)
single oper‐
ating
energy
2)
t / ms
W
/ J
max
30
62
40
270
25
568
50
1065
50
1548
40
2000
60
4800
60
6658
80
8700
Total operat‐
ing energy
(service life)
W
/ kJ
total
5
35
284
774
774
1800
2400
2400
3800
49