Connecting
6.3 System integration
Establishing a SPEED-CONNECT connection
Procedure
Note
• Only tighten the connector by hand.
• Do not use any wrenches or similar tools.
1. Ensure that the union nut of the SPEED-CONNECT connector is rotated to the end stop in the
direction of the "open" arrow.
2. Align the SPEED-CONNECT connector so that the triangles on the top of the connectors are
opposite one another.
3. Push the power connector onto the motor connecting socket as far as it will go.
4. Turn the union nut by hand in the direction of "close" by at least 45° (position A) or up to the
end stop (position B)
Note
A secure connection is only guaranteed from position A onward.
You have established a secure connection.
Releasing a SPEED-CONNECT connection
Procedure
78
A
Minimum locking
B
Maximum locking up to the end stop
SIMOTICS S-1FK2 synchronous motors for SINAMICS S120
Operating Instructions, 02/2022, A5E46089564B AD