Delta A9000 User Manual page 96

Ac power source
Table of Contents

Advertisement

User Manual
A9000
AC Power Source
[SOURce:]VOLTage:RANGe
Function :Set (query) output voltage range
LOW
Voltage range(V)
0.0 ~ 150.0
Example :[SOURce:]VOLTage:RANGe?
Parameter :LOW | HIGH
Parameter returns
[SOURce:]VOLTage:SENSe
Function :Set (query) remote sense function. REMOTE is in enable, VOUT is in disable.
Example :[SOURce:]VOLTage:SENSe?
Parameter :VOUT | REMOTE
Parameter returns
[SOURce:]CONFigure:INHibit?
Function :Set (query) remote TTL inhibition operation. Refer paragraph 3.6.3 for details.
Example :[SOURce:]CONFigure:INHibit?
Parameter :OFF | LIVE | TRIG | EXCITE
Parameter returns
[SOURce:]PHASe:ON
Function :Set (query) waveform start phase angle set at main manual.
Example :[SOURce:]PHASe:ON?
Parameter :<NR2>, effective range:0.0 ~ 359.9
Parameter returns
93
│ www.deltaww.com
Current range(A)
0.0 ~ 96.0
[SOURce:]VOLTage:RANGe HIGH
:LOW | HIGH
[SOURce:]VOLTage:SENSe REMOTE
:VOUT | REMOTE
[SOURce:]CONFigure:INHibit LIVE
:OFF | LIVE | TRIG | EXCITE
[SOURce:]PHASe:ON 200.5
:<NR2>
HIGH
Voltage range(V)
0.0 ~ 300.0
Current range(A)
0.0 ~ 48.0

Advertisement