AC Power Source
[SOURce:]STEP:DFRequency
Function : Set (query) frequency change for each step in STEP mode.
Example : [SOURce:]STEP:DFRequency?
Parameter : <NR2> effective range:-150.0 ~ 150.0(unit:HZ)
Parameter returns
[SOURce:]STEP:SPHase
Function : Set(query) start phase angle at STEP mode.
Example : [SOURce:]STEP:SPHase?
Parameter : <NR2> effective range:0.0 ~ 359.9
Parameter returns
[SOURce:]STEP:DWELl
Function : Set (query) output duration for each step in STEP mode.
Example : [SOURce:]STEP:DWELl?
Parameter : <NR2> effective range:1 ~ 16000000 (unit:ms)
Parameter returns
[SOURce:]STEP:COUNt
Function : Set (query) how many steps to execute STEP mode.
Example : [SOURce:]STEP:COUNt?
Parameter : <NR1> effective range:0 ~ 10000
Parameter returns
99
│ www.deltaww.com
[SOURce:]STEP:DFRequency -10.5
:<NR2>
[SOURce:]STEP:SPHase 80.5
:<NR2>
[SOURce:]STEP:DWELl 1000.5
:<NR2>
[SOURce:]STEP:COUNt 500
:<NR1>