Delta A9000 User Manual page 101

Ac power source
Table of Contents

Advertisement

User Manual
A9000
AC Power Source
[SOURce:]PULSe:PERiod
Function : Set (query) total period of PULSE mode
Example : [SOURce:]PULSE:PERiod?
Parameter : <NR1> Effective range:2 ~ 16000000 (unit: msec)
Parameter returns
[SOURce:]STEP:VOLTage:AC
Function : Set (query) start voltage for STEP mode.
Example : [SOURce:]STEP:VOLTage:AC?
Parameter : <NR2> effective range:0.0 ~ 150.0 (low level range),
Parameter returns
[SOURce:]STEP:DVOLtage:AC
Function : Set (query) voltage change for each step in STEP mode.
Example : [SOURce:]STEP:DVOLtage:AC?
Parameter : <NR2> effective range:-150.0 ~ 150.0(unit:Volt)
Parameter returns
[SOURce:]STEP:FREQuency
Function : Set (query) start frequency for STEP mode
Example : [SOURce:]STEP:FREQuency?
Parameter : <NR2> effective range:30.0 ~ 1000.0 (unit : Hz)
Parameter returns
98
│ www.deltaww.com
[SOURce:]PULSE:PERiod 600
:<NR1>
[SOURce:]STEP:VOLTage:AC 150.5
0.0 ~ 300.0 (high level range)
:<NR2>
[SOURce:]STEP:DVOLtage:AC 20.5
:<NR2>
[SOURce:]STEP:FREQuency 80.5
:<NR2>