[SOURce:]LIST:DWELl
Function : Set (query) execution time for 10 individual sequences in SERIES mode.
Example : [SOURce:]LIST:DWELl?
parameter :<NR2>, ..., <NR2> effective range:0 ~ 16000000 (unit: msec)
Parameter returns
[SOURce:]LIST:SHAPe
Function : Set (query) waveform buffer used for 10 individual sequences in SERIES mode.
Example : [SOURce:]LIST:SHAPe?
Parameter :A|B, ..., A|B
Parameter returns
[SOURce:]LIST:VOLTage:AC: STARt
Function : Set (query) start voltage for 10 individual sequences in SERIES mode.
Example : [SOURce:]LIST:VOLTage:AC: STARt?
Parameter : <NR2>, ..., <NR2> effective range:0.0 ~ 150.0 (low voltage range),
Parameter returns
[SOURce:]LIST:VOLTage:AC: END
Function : Set (query) stop voltage for 10 individual sequences in SERIES mode.
Example : [SOURce:]LIST:VOLTage:AC: END?
Parameter : <NR2>, ..., <NR2> effective range:0.0 ~ 150.0 (low voltage range),
Parameter returns
95
│ www.deltaww.com
[SOURce:]LIST:DWELl 16000000 1 23 95
:<NR2>, ..., <NR2>
[SOURce:]LIST:SHAPe A B A A A
:A|B, ..., A|B
[SOURce:]LIST:VOLTage:AC: STARt 110 22.5 55.6
0.0 ~300.0 (high voltage range)
:<NR1>, ..., <NR2>
[SOURce:]LIST:VOLTage:AC: END 1.2 50 66.6
0.0 ~300.0 (high voltage range)
:<NR2>, ..., <NR2>