User Manual
A9000
AC Power Source
Parameter :<NR2>, effective range:0.00 ~ 64.00 (150V range),
Parameter returns
[SOURce:]CURRent:DELay
Function : Set (query) delay time to trigger software over current protection
Example : [SOURce:]CURRent:DELay?
Parameter : <NR2>, Effective range:0.0 ~ 9.0 (unit: Sec)
Parameter returns
[SOURce:]CURRent:INRush:STARt
Function : Set (query) time to start measure inrush current
Example : [SOURce:]CURRent:INRush:STARt?
Parameter : <NR2>, effective range:0.0 ~ 9000.0 (unit: msec)
Parameter returns
[SOURce:]CURRent:INRush:INTerval
Function : Set (query) inrush current measurement time
Example : [SOURce:]CURRent:INRush:INTerval?
Parameter : <NR2>, effective range:0.0 ~ 9000.0 (unit: msec)
Parameter returns
[SOURce:]FREQuency
Function : Set (query) frequency of output waveform
Example : [SOURce:]FREQuency?
Parameter : <NR2>, effective range:30.0 ~ 1000.0 (unit: Hz)
Parameter returns
90
│ www.deltaww.com
0.00 ~ 32.00 (300V range)
:<NR2>
[SOURce:]CURRent:DELay 1.2
:<NR2>
[SOURce:]CURRent:INRush:STARt 200.3
:<NR2>
[SOURce:]CURRent:INRush:INTerval 400.8
:<NR2>
[SOURce:]FREQuency 50.8
:<NR2>