A9000
AC Power Source

6.3.2.4 Other Commands

Followings are other commands instruction, example and returned parameter:
TRIG
Function : Set (query) trigger status. Disabled when OUTPut:MODE = FIXE
Example : TRIG?
Parameter : OFF | ON
Parameter returns
NPHase
Function : Set output mode:
Example : NPHase?
Parameter : SINGLE | THREE.SYN | THREE.INDIV
Parameter returns
Note
VERion:DSP?
Function : Query firmware version.
Example : VERion:DSP?
Parameter returns
101
│ www.deltaww.com
TRIG ON
:OFF | RUNNING
 SINGLE
 THREE.SYN
 THREE. INDIV
NPHase SINGLE
:SINGLE | THREE.SYN | THREE.INDIV
: It needs 800msec to make this command take effect, please reserve delay
time to make sure operation normally.
:S00E02
: Outputs in single phase (parallel)
: Three phase output. Only phase 1 need to set voltage
and frequency. Voltage and frequency of phase 2 and
3 changes according to setting of phase 1
: Three phase output. Voltage and frequency forthree
phase can be set independently.
Query output mode
set output as single phase