A9000
AC Power Source
[SOURce:]PULSe:FREQuency
Function : Set (query) frequency of PULSE waveform.
Example : [SOURce:]PULSE:FREQuency?
Parameter : <NR2> Effective range:30.0 ~ 1000.0 (unit: Hz)
Parameter returns
[SOURce:]PULSe:SPHase
Function : Set (query) start phase angle of PULSE waveform.
Example : [SOURce:]PULSE:SPHase?
Parameter : <NR2> effective range:0.0~ 359.9
Parameter returns
[SOURce:]PULSe:COUNt
Function : Set (query) how many times to execute PULSE voltage.
Example : [SOURce:]PULSE:COUNt?
Parameter : <NR1> Effective range:0 ~ 10000
Parameter returns
[SOURce:]PULSe:DCYCle
Function : Set (query) execution time of PULSE waveform, it must be no longer than
Example : [SOURce:]PULSE:DCYCle?
Parameter : <NR1>, effective range:1 ~ 15999999 (unit: msec)
Parameter returns
97
│ www.deltaww.com
[SOURce:]PULSE:FREQuency 50.0
:<NR2>
[SOURce:]PULSE:SPHase 60.0
:<NR2>
[SOURce:]PULSE:COUNt 500
:<NR1>
total period in PULSE mode.
[SOURce:]PULSE:DCYCle 300
:<NR1>