Delta A9000 User Manual page 63

Ac power source
Table of Contents

Advertisement

User Manual
A9000
AC Power Source
LIST mode provide 10 sets of programmable waveform(SEQ-0 ~ SEQ-9). Output
waveforms start from SEQ-0, then SEQ-1、SEQ-2... in orders until time parameter (Time)
of SEQ-n being processed is 0 or SEQ-9 is finished outputting, then one List waveform
output is completed.
Following are definitions for all parameters:
Parameter
Count
V Start
V End
F Start
F End
Time
Waveform
Degree On
After SEQ setting is completed, press
below:
60
│ www.deltaww.com
L I S T
C o u n t :
G o
t o
T r i g g e r
Definition
Execution times for one complete List waveform.
P r e s s
When 0 is setting, output recycles endless until user
press
to stop.
Enter
L I S T
S E Q
-
0
Start voltage(V)
V
S t a r t
Stop voltage(V)
V
E n d
Start frequency(Hz)
F
S t a r t
F
E n d
Stop Frequency(Hz)
T i m e
Output duration (msec)
W a v e f o r m
Output waveform selection
D e g r e e
Start phase angle for output waveform(deg)
P r e s s
L I S T
C o u n t :
G o
t o
T r i g g e r
P r e s s
L I S T
T r i g g e r
O u t p u t
R e p o r t : ( O v e r v i e w )
M e t e r
V Φ1 :
V Φ2 :
1
M o d e
t o
S w i t c h
:
1 0 0 . 0 V
:
5 0 . 0 V
:
1 0 0 . 0 H z
:
5 0 . 0 H z
:
1
:
A
O n :
0 . 0
t o
S w i t c h
ESC/
back to LIST mode initialization page as
Cancel
1
M o d e
t o
S w i t c h
O N ∕O F F : O F F
S t a t u s : S t o p
0 . 0
I Φ1 :
0 . 0
I Φ2 :
Min
0
P a g e
0.0
0.0
30.0
30.0
m s
0
A or B
0.0~
P a g e
P a g e
0 . 0 0
0 . 0 0
Range
Max
10000
300.0
300.0
1000.0
1000.0
60000
359.9