Page 1
SERVICE MANUAL MODEL DEST......JME-SA200 World SCREEN ALIGNMENT CONTROLLER...
Page 2
CRITICAL TO SAFE OPERATION. REPLACE THESE COMPO- LES SCHÉMAS DE PRINCIPE, LES VUES EXPLOSÉES ET LES NENTS WITH SONY PARTS WHOSE PART NUMBERS APPEAR LISTES DE PIECES SONT D’UNE IMPORTANCE CRITIQUE AS SHOWN IN THIS MANUAL OR IN SUPPLEMENTS PUB- POUR LA SÉCURITÉ...
Page 6
Overview The model and serial numbers are located on the rear. Record the serial number in the space provided below. Refer to these numbers whenever you call upon your Sony About This Manual ............5 dealer regarding this product. Model No. JME-SA200 Serial No.
• Do not use the unit in high humidity. Checking the Screen Display Unit ......... 34 If any abnormality occurs, turn off the power and consult with qualified Sony service personnel. Adjusting the Luminance of a Specified Unit or Cell ... 36 On cleaning Registering and Recalling the Unit/Cell Numbers ..
Overview of the JumboTron System The JumboTron system displays video images on a large screen Structure of the JumboTron screen (JumboTron screen) located either outdoors or indoors. Images from video sources such as a VCR, video camera and computer can be displayed on Two types of the JumboTron screen are available.
Features Overview of the JumboTron System The JME-SA200 screen alignment controller is designed to check the Configuration of the JumboTron system operation of the JumboTron screen and to adjust the position, size, brightness and picture quality of the image. The wireless remote control The following is the suggested configuration of the JumboTron system.
Locations and Functions of Parts and Controls Power Source The NP-F750 rechargeable battery pack (not supplied) is used for the Front panel power source of this unit. Before attaching the battery pack, charge it using the AC-V615 AC power adaptor (not supplied). Rear panel For charging and details of the use of the battery pack, refer to the Operating Instructions supplied with the rechargeable battery pack and the AC power...
Connections Detaching the battery pack JumboTron system configuration The Sony distributor will take care of all the connections for the whole While pressing the BATT EJECT lever downward, slide the battery pack JumboTron system. in the direction of the arrow and lift it.
Prepare a cellular phone, digital data card and connecting cable (not digital data card. supplied). For usable equipment, consult with your Sony distributor. Insert the dummy card into the slot. Press the EJECT button using the supplied eject tool, and remove the dummy card.
Registering the Phone Number for the Modem Connections Register the phone number for the modem connected to the ICU controller Connections for using as wired controller to this unit. Once it is registered, the unit automatically starts dialing when the power is turned on. The unit can be used as a wired remote controller by connecting to the JTC-C200 ICU controller.
Attaching the Shoulder Strap Registering the Phone Number for the Modem Input the phone number using the F1 to F5 buttons and v/V buttons. Attach the supplied shoulder strap to the shoulder strap attachments and Each function button can be used to input two types of numbers: first, adjust its length.
Preparing the System Communicating with the ICU Controller Do the following before remote control operation with this unit. When performing adjustment with this unit, first establish communication For details, read the Operating Instructions supplied with the JTC-C200 with the JTC-C200 ICU controller. ICU controller.
Setting the Information about the Screen Communicating with the ICU Controller Notes Before using the unit, set the information about your JumboTron system, such as the number of display units constituting the screen. If the correct • The time required for establishing communication depends on the information is not set, the adjustments cannot be performed correctly.
Selecting the Screen Display Mode and Input Signal Setting the Information about the Screen To return to the MAIN MENU Like the JTC-C200 ICU controller, you can select the screen display mode Press the MENU button. for the images to be displayed on the screen and the type of the video input signal with this unit.
Adjusting the Image Position and Size on the Screen You can shift the position of the image on the screen vertically and After adjustment, press the ENTER button. horizontally, and expand or reduce its size. The adjusted data can be The adjusted data are stored to the currently selected memory number.
Adjusting the Picture on the Screen Adjusting the Image Position and Size on the Screen You can check the information about the input signal and picture quality of Selecting the memory number/adjusting the screen by recalling the the image on the screen in the display window of the unit. stored conditions You can also adjust the picture quality: color, hue and sharpness for the composite video signal, or color and hue for the component signal.
Adjusting the Brightness of the Screen Adjusting the Picture on the Screen You can adjust the brightness of the screen to 16 levels. Perform the Adjusting the color, hue and sharpness adjustment when the image to be adjusted is displayed on the screen. Press the v or V button to select the item you want to adjust and press Establish communication with the ICU controller (page 21) and the B or b button to adjust it.
Adjusting the Computer Graphics and Video Image Mix Level You can display a video image over the monochrome portion of a Set the MAX and MIN levels of R, G and B. computer graphics image by selecting the MIX mode on the JTC-C200 or Press the v or V button to select the MIX LEVEL item you want to the INPUT-1&2 mode on this unit.
Checking the Screen Display Unit Assign the unit number. You can display the test patterns automatically and repeatedly on a Press the v or V button to select X or Y of UNIT NUMBER and press specified screen display unit to check if the unit is operating properly. the B or b button to change the number.
Adjusting the Luminance of a Specified Unit or Cell Press the ENTER button. If the brightness or the color temperature of the image on the screen differs The whole screen turns to the selected adjustment color. partially, you can adjust the luminance of a specified unit or cell. The display window proceeds to the adjustment menu (SCREEN The luminance adjustment can be performed for the R, G and B colors UNIT/ADJUST).
Registering and Recalling the Unit/Cell Numbers Adjusting the Luminance of a Specified Unit or Cell Adjust the luminance. The JME-SA200 can register up to 256 unit/cell numbers to be stored in Press the B or b button to adjust the luminance by observing the memory.
Registering and Recalling the Unit/Cell Numbers Press the v or V button to select CONTRAST and press the B or b Recalling the registered unit or cell button to set the luminance level of the whole screen. Set to the luminance level at which you can easily observe the display mode.
Adjusting the Monitor Registering and Recalling the Unit/Cell Numbers Recall the registered units/cells one by one. You can adjust the position of the image and its boundary on the monitor As you press the b button, the registered unit/cell numbers are recalled connected to the JTC-P200 ICU.
Adjusting the Monitor After adjustment, press the ENTER button. Selecting the memory number/adjusting the monitor by recalling the The adjusted data are stored to the currently selected memory number. stored conditions To return to the MAIN MENU By selecting the memory number, you can change the monitor screen to Press the MENU button.
Cutting Off the Image from the Screen Displaying the Unit Address on the Screen You can make the image on the screen disappear. This function is useful You can display the numbers set by the address switches located on the when you check the light-emitting condition of the screen.
Troubleshooting Displaying the Software Version of the JME-SA200 You can display the version of the software installed in this controller in If you think you have a problem during operation, check through the following list. the display window. Establish communication with the ICU controller (page 21) and Problem Cause Corrective action...
Specifications General Pin assignment Power requirements CONTROL connector (D-sub 15-pin) Lithium-ion battery Power consumption DC 7.2 V, 0.75 A 279 × 158 × 55.8 mm (w/h/d) Dimensions (11 × 6 × 2 inches) not including the battery pack Mass Approx. 1.3 kg (2 lb 14 oz) not including the battery pack Pin No.
2-2-2. CPU and SAP Boards Removal 1 Four screws (+PSW2.5 x 6) 2 CPU board SAK board 3 Four screws (+BVTP3 x 10) 4 SAP board Rear cover JME-SA200 2-3(E)
CHASSIS SECTION 5 EXPLODED VIEWS NOTE: • Items with no part number and no description are not stocked because they are seldom required for routine service. • The construction parts of an assembled part are indicated with a collation number in the remark column.
SECTION 6 Rf.NO. PART NO. DESCRIPTION REMARK Rf.NO. PART NO. DESCRIPTION REMARK ELECTRICAL PARTS LIST NOTE: • Items marked " * " are not stocked since RESISTORS The components identified ! marked are they are seldom required for routine • All resistors are in ohms critical for safety.
SECTION 8 DIAGRAMS 8-1. SCHEMATIC DIAGRAMS AND PRINTED WIRING BOARDS Note: • All capacitors are in µF unless otherwise noted. pF: µµF 50 WV or less are not indicated except for electrolytics. • All electrolytics are in 50 V unless otherwise specified. •...
Page 48
– A SIDE – SUFFIX: -11 – B SIDE – SUFFIX: -11 JME-SA200...