Design and principle of operation
Type 3730-3 Positioner
Temperature
Influenc-
Supply air
es
Effect of vibration
Electromagnetic compatibility
Electrical connections
Degree of protection
Use in safety-instrumented
systems (SIL)
Emergency venting at 0 mA set
point and using optional
solenoid valve
Explosion protection
Communication (local)
Software requirements (SSP)
Communication (HART
®
For handheld
communicator
Software
require-
ments
For computer
Binary contacts
For connection to
Two software limit switches, reverse polarity protection, floating, configurable switching characteristics (default set-
tings in table)
Version
Signal
No response
state
Response
3-6
The technical data for the explosion-protected devices may be restricted by the
limits specified in the test certificates.
≤0.15 %/10 K
None
≤0.25 % up to 2000 Hz and 4 g according to IEC 770
Complying with EN 61000-6-2, EN 61000-6-3, EN 61326-1 and NAMUR Rec-
ommendation NE 21
One M20x1.5 cable gland for 6 to 12 mm clamping range
Second M20x1.5 threaded connection additionally available
Screw terminals for 0.2 to 2.5 mm² wire cross-section
IP 66/NEMA 4X
Observing the requirements of IEC 61508, the systematic capability of the pilot
valve for emergency venting as a component in safety-instrumented systems is giv-
en.
Use is possible on observing the requirements of IEC 61511 and the required
hardware fault tolerance in safety-instrumented systems up to SIL 2 (single device/
HFT = 0) and SIL 3 (redundant configuration/HFT = 1).
Refer to Table 3-3
SAMSON SSP interface and serial interface adapter
TROVIS-VIEW with database module 3730-3
HART
Revision 5 (can be switched to Revision 6)
®
)
Impedance in HART
115 Ω
Device description for Type 3730-3
DTM file according to specification 1.2, suitable for integrating the device into
frame applications that support the use of FDT/DTM (e.g. PACTware); other inte-
grations (e.g. AMS, PDM) available
For connection to the binary input of the PLC
acc. to IEC 61131-2, P
connection to NAMUR switching amplifier
acc. to EN 60947-5-6
No explosion protection
Non-conducting
Conductive (R = 348 Ω)
frequency range: Receiving 350 to 450 Ω · Sending approx.
®
= 400 mW or for
max
NAMUR switching amplifier acc.
to EN 60947-5-6
Ex
≤1.0 mA
≥2.2 mA
EB 8384-3 EN