(3) Air Filter Element Cleaning/Replacement
Clean
Every 200 hours
Replace
Every 500 hours
Remove the air cleaner clips and cleaner cap.
1
Remove the element.
2
Clean or replace the element. Replace by
3
performing the above procedures in reverse
order.
< Note >
 Always be sure to turn the cleaner cap in the direction
indicated by the arrow.
 Replace the elements earlier if using in an excessively
dusty location.
 Do not add oil as this generator uses a dry element.
 Clear foreign material by pinching the vacuator valve once a week in normal operating
conditions or daily if operating in a location that is excessively dirty or dusty. Wipe away any
dirt or moisture that has adhered to the parts.
 Never touch the elements for any reason except cleaning.
 Element part no.: P828889 (ISUZU part no.)
 Cleaning the air filter element
If dry dust is adhering : Blow comprgssed air from inside the element.
If carbon or oil is adhering : Replace with new parts.
(4) Draining Water from the Water Separator
Check
Clean
Every 200 hours
Set a container to catch spilled water.
1
Loosen the air bleeder plug of the fuel filter sufficiently.
2
Loosen the valve on the bottom to drain water.
3
Tighten the valve after drained the water.
4
■Faucet tightening torque :
1.5 to 2.5N・m(0.15 to 0.25kgf・m)
Tighten the air-bleeding plug.
■Air bleeding plug tightening torque :
8 to 12N・m(0.8 to 1.2kgf・m)
< Note >
 After reset the plug and the valve, be sure to always start the engine and check that there is no
fuel leakage.
 If water is accumulate in the cup, draining water from the fuel tank.( Refer to section "(7)
Draining Water from the Fuel Tank".)
 Be careful not to over-tighten the drain plug and air bleeder plug.
 Always be sure to wipe up any spilled fuel.
Daily
37
Air Cleaner
Cap
Air Filter Elements
Vacuator Valve
Air Cleaner Cap
Clip
Air Bleeder
Plug
Valve