TROUBLESHOOTING

Phenomenon
The pictures copied to the
CompactFlash card are not the ones
displayed on the monitor.
Setup menus supplied from the Matrix
Switcher cannot be recorded.
The recorded channel # differs from the
original supplied from the video multi-
plexer.
VMD does not function.
T & D or status display is pushed out of
the display range on the monitor.
The bottom portion of the playback pic-
ture on the monitor is darker.
Error message appears saying "TEM-
PERATURE ERROR SYSTEM
STOPPED".
Alarm recording does not function in a
system including a video multiplexer.
42
Cause
The monitor receives the multiscreen-
out signal from the video multiplexer.
The WJ-HD100 does not record non-
interlace video.
This may happen when the video multi-
plexer is connected with CAMERA SW
OUT, and the field rate is set to 10 fps
or faster.
VMD does not function in playback.
This may happen with some monitors.
This may happen with some monitors,
WJ-HD100 records up to 234H per
field.
Ventilation is blocked.
Failure of cooling fan
The ALARM IN signal has the wrong
polarity for the WJ-HD100.
What to do
Connect the video monitor directly with
the WJ-HD100.
Set the field rate to 7.5 fps or slower.
Stop playback.
Adjust the scan size of the video moni-
tor.
Remove obstacles placed near ventila-
tion openings and the fan.
Contact your dealer for replacement of
the fan.
Set the ALARM OUT switch (SW3)
inside the video multiplexer to O.C.
referring to the manual.