4
Fully extend the rebound damper shaft. Push the syringe plunger
down, then release the plunger. Allow the bladder to expand and
retract until it stops in a resting position.
5
Unthread the syringe bleed fitting from the bleed port.
⚠ CAUTI ON - EYE HAZARD
Oil may eject from the bleed port if the bladder is not in a resting
position. Wear safety glasses.
6
Install the bleed screw and tighten it.
Wipe away any excess oil.
T10
T10
1.1-2.3 N·m (10-20 in-lb)