Siemens SIMATIC ET 200SP Manual page 61

Technology module tm poslnput 1
Hide thumbs Also See for SIMATIC ET 200SP:
Table of Contents

Advertisement

Bit →
Bit 7
Byte ↓
10...15
10
Set output (DQ1):
0000
: Use by user program
B
0001
: Between comparison value and high counting
B
limit; Measuring: Measured value >= comparison value
0010
: Between comparison value and low counting
B
limit; Measuring: Measured value <= comparison value
0011
: At comparison value for a pulse duration
B
0100
: Between comparison value 0 and 1
B
0101
: After set command from CPU until comparison
B
value
0110
: Not between comparison value 0 and 1
B
0111 to 1111
: Reserved
B
11
Count direction (DQ1):
00
: Reserved
B
01
: Forward
B
10
: Backward
B
11
: In both directions
B
12
13
14
15
16
16
Behavior of
counter
value after
Capture
3)
(DI0):
0
:
B
Continue
counting
1
: Set to
B
start value
and
continue
counting
Technology module TM PosInput 1 (6ES7138-6BA00-0BA0)
Manual, 02/2014, A5E33015755-AA
Bit 6
Bit 5
Count direction (DQ0):
00
: Reserved
B
01
: Forward
B
10
: Backward
B
11
: In both directions
B
WORD: Value range in ms/10: 0 to 65535
WORD: Value range in ms/10: 0 to 65535
Edge selection (DI0):
00
: Reserved
B
01
: At rising edge
B
10
: At falling edge
B
11
: At rising and falling
B
edge
Bit 4
Bit 3
Behavior of a DQ
Set output (DQ0):
0000
: Use by user program
B
0001
: Between comparison value and high counting
B
limit; Measuring: Measured value >= comparison value
0010
: Between comparison value and low counting
B
limit; Measuring: Measured value <= comparison value
0011
: At comparison value for a pulse duration
B
0100
: Reserved
B
0101
: After set command from CPU until comparison
B
value
0110 to 1111
Reserved
2)
Pulse duration (DQ0):
Pulse duration (DQ1):
Behavior of DI0
Select level
Reserved
2)
(DI0):
0
: Active
B
with high
level
1
: Active
B
with low
level
Parameter data records
Bit 2
Bit 1
: Reserved
B
Reserved
Substitute
2)
value for
DQ1
D
D
Set function of DI (DI0):
000
: Gate start/stop (level-triggered)
B
001
: Gate start (edge-triggered)
B
010
: Gate stop (edge-triggered)
B
011
: Synchronization
3)
B
100
: Enable synchronization at
B
signal N
3)
101
: Capture
B
110
: Digital input without function
B
111
: Reserved
B
Bit 0
Substitute
value for
DQ0
3)
3)
3)
61