Trunk Status Read - Samsung OfficeServ 500 Programming Manual

Hide thumbs Also See for OfficeServ 500:
Table of Contents

Advertisement

CHAPTER 2. Ошибка! Стиль не определен.

[409] TRUNK STATUS READ

Allows the status of trunks to be read in a format that will enable the servicing personnel to
quickly identify the ownership and position of a trunk. This is a read-only MMC.
No
00
PORT
01
TYPE
02
1A2 EMULATE
03
TRK FORWARD
04
LINE
05
DIAL
06-11
TOLL TYPE 1-6
12-17
RING PLAN 1-6
18
MOH SOURCE
19
DISA LINE
CONDITIONS
NONE
DEFAULT DATA
FOLLOW TRUNK
ACTION
1) Press Transfer button and enter 409.
Display shows:
2) Enter trunk number via dial keypad.(e.g., 704)
OR
Press Volume button to make selection and press
Right Soft button to advance cursor.
3) Enter in desired option 00-12.(e.g., 02)
OR
Press Volume button to make selection.
4) Press Transfer button and enter to exit.
OR
Press Speaker button to advance next MMC.
2-118
Type
Port Number(Cabinet/Slot/Port)
LOOP, GND, E & M, DID, BRI, PRI, VOIP
1A2 Emulation On/Off
Trunk Forward On/Off
CO/PBX
DTFM/Dial Pulse
Ring Plan Toll Restriction(1-6)
Ring Plan Ring Destination(1-6)
MOH Source
DISA Status
Description
DISPLAY
[701] TRK STATUS
PORT:C1-S5-P01
[704] TRK STATUS
PORT:C1-S5-P04
[704] TRK STATUS
TYPE:LOOP TRUNK
© SAMSUNG Electronics Co., Ltd.