Setup; Equipment; Grounding - Graco King E60 Operation

Electric driver
Hide thumbs Also See for King E60:
Table of Contents

Advertisement

Setup

Setup
Setup
See Driver Installation manual for power requirements
for hazardous locations/explosive atmospheres.
Installation of this equipment involves potentially
hazardous procedures. Only trained and qualified
personnel who have read and who understand
the information in this manual should install this

equipment.

Install
Install
Install Vented
Vented
Vented Oil
Oil Cap
Oil
Equipment
Equipment
Equipment
The temporary unvented cap (PX) prevents oil
leaks during shipment. This temporary cap must be
replaced with the supplied vented oil cap (P) before
use.
ti31010a
3A8124A
Cap Before
Cap
Before Using
Before
Using
Using

Grounding

Grounding
Grounding
This equipment must be grounded to reduce the
risk of static sparking and electric shock. Electric
or static sparking can cause fumes to ignite or
explode. Improper grounding can cause electric
shock. Grounding provides an escape wire for the
electric current.
Driver: The driver is grounded through the power
Driver:
Driver:
cord.
Driver (optional
(optional secondary):
secondary): Two ground terminals
Driver
Driver
(optional
secondary):
are provided if local code requires redundant
grounding connections.
Loosen the ground screw (ZZ) and attach a ground
wire (Graco part 244524 - not supplied). Tighten the
ground screw securely. Connect the other end of the
ground wire to a true earth ground.
Setup
7