Position Sensor
Sensor Replacement
Position
Position
Sensor

(24W120)

(24W120)
(24W120)
NOTICE
NOTICE
NOTICE
To avoid damage to the encoder and control board,
wear grounding strap (Graco Part No. 112190 –
not supplied) and ground appropriately.
Overview
Overview
Overview
The position sensor is used to determine where the
driver output shaft (H) is in the stroke.
Tools Required
Required
Tools
Tools
Required
• 6 mm Hex Wrenches
• 13 mm Open-Ended Wrench
• 6 mm Open-Ended Wrench
• Phillips Screwdriver (#2)
• Torque Wrench (15 ft-lb, 20 N•m)
3A8124A
Replacement
Replacement
Prepare
Prepare Driver
Prepare
Driver
Driver
1. Remove power from the driver. Follow
appropriate lock-out/tag-out procedures. Wait
five minutes before servicing.
2. Follow the
Pressure Relief Procedure, page 8
3. Decouple the pump lower from the driver per the
system manual.
Remove Electronics
Electronics Cover
Remove
Remove
Electronics
NOTICE
NOTICE
NOTICE
To avoid equipment damage, carefully support the
cover when removing the last bolt. Hold the cover
horizontally and take care that the wires are not
pulled tight.
1. Remove the 12 bolts (CB) that hold on the
electronics cover using a 6 mm hex wrench.
Place bolts in a safe location.
2. Pull the cover straight off of the alignment pins
that hold the cover in place.
3. Support the cover after it has been removed to
prevent putting excess strain on the wires inside.
Repair
Cover
Cover
.