YASKAWA CIMR-SSA Series Instruction Manual page 87

Table of Contents

Advertisement

Constant
Name
No.
L1-01
Motor protection selection
L1-02
Motor protection time
L2-01
Momentary power loss detection
L2-02
Momentary power loss ridethru time
Deceleration time at momentary pow-
L2-03
er loss
L2-05
Undervoltage detection level
Overvoltage prevention function
L3-01
*3
selection
L4-01
Speed detection level
L4-02
Speed detection width
L4-03
Speed detection level (+/-)
L4-04
Speed detection width (+/-)
Operation when speed reference is
L4-05
missing
L5-01
Number of auto restart attempts
L5-02
Auto restart operation selection
L6-01
Torque detection selection 1
L6-02
Torque detection level 1
L6-03
Torque detection time 1
L6-04
Torque detection selection 2
L6-05
Torque detection level 2
L6-06
Torque detection time 2
L7-01
Forward torque limit
L7-02
Reverse torque limit
L7-03
Forward regenerative torque limit
L7-04
Reverse regenerative torque limit
Protect selection for internal DB resis-
L8-01
*4
tor
L8-02
Inverter overheat pre-alarm level
Operation selection after inverter over-
L8-03
heat pre-alarm
L8-05
Input open-phase protection selection
Output open-phase protection selec-
L8-07
tion
L8-10
Ground fault protection selection
L9-01
Step-out protection selection
Output current unbalance protection
L9-02
*6
selection
88
Table A−5 Constants List (Cont'd)
Initial
User
Setting
Setting
1
60.0
0
*1
30.0
*2
190
1
0.0
2.0
0.0
2.0
0
0
0
0
150
0.1
0
150
0.1
160
160
160
160
0
95
3
0
0
1
1
1
*1
Setting range and initial setting differ depending on inverter capacity.
*2
Set value for 200V class. For 400V class, the value is twice as that of 200V class.
*3
When using a braking resistor unit, set L3-01 to "0."
*4
When using a mounting-type braking resistor unit (model ERF), set L8-01 to "1."
*5
Not initialized.
*6
The display is applicable for software No. 1033 or later (FLASH side). To check which
version is being used, refer to U1-14.
Constant
Name
No.
o1-01
Monitor selection
o1-02
Monitor selection after power up
Units of speed reference setting and
o1-03
monitor
o2-01
LOCAL/REMOTEkeyenable/disable
STOP key during control circuit termi-
o2-02
nal operation
o2-04
kVA selection
Speed reference setting method selec-
o2-05
tion
Operation selection when digital opera-
o2-06
tor is disconnected
o2-07
Cumulative operation time setting
o2-08
Cumulative operation time selection
T1-02
Tuning mode
T1-03
Tuning item selection
Initial
User
Setting
Setting
6
1
1
1
0
*1 *5
0
0
0
0
1

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents