Appendix 4 Constants List - YASKAWA CIMR-SSA Series Instruction Manual

Table of Contents

Advertisement

APPENDIX 4
The numbers of constants displayed in the digital operator depend on the setting of constant access
level (A1-01). For details, refer to Descirptive Manual for Constants.
Constant
No.
No.
U1-01
Speed reference
U1-02
Output frequency
U1-03
Output current
U1-04
Control method
U1-05
Motor speed
U1-06
Output voltage reference
U1-07
DC bus voltage
U1-08
Output power
U1-09
Torque reference (internal)
U1-10
Input terminal status
U1-11
Output terminal status
U1-12
Operation status
U1-13
Cumulative operation time
U1-14
Software No. (at FLASH side)
U1-15
Control circuit terminal 13 input voltage
U1-16
Control circuit terminal 14 input current/voltage
U1-17
Control circuit terminal 16 input voltage
U1-18
Motor q-axis current (Iq)
U1-19
Motor d-axis current (Id)
U1-20
Speed reference after soft-start
U1-21
ASR input (speed deviation)
U1-22
ASR output
Monitor
U1-27
q-axis current reference
U1-28
d-axis current reference
U1-29
Voltage limit control output
U1-30
q-axis current control output
U1-31
d-axis current control output
U1-32
Output voltage reference Vq
U1-33
Output voltage reference Vd
U1-36
Output voltage phase
U1-37
Magnetic-pole position detection value (with PG)
U1-38
Magnetic-pole position detection estimated value (without PG)
U1-41
LED check (diagnosis)
U1-42
Operation status 2
U1-43
Command 1 from transmission option
U1-44
Command 2 from transmission option
U1-45
External torque reference
U1-46
Torque compensation
U1-47
DO-08/H output status
U1-48
Momentary power loss drop amount
U1-49
Software No. (at CPU side)
U1-50
Speed detection PG counter value
U1-51
Output current phase
U1-53
PID feedback amount
U1-54
DI-16H input status
84
CONSTANTS LIST
Table A−4 Monitor Item List
Name
*1
Even if f is indicated, some constants are not displayed depending on access level.
*2
The unit varies depending on the setting of o1-03.
*3
0.01A for models of 7.5 kW or below.
Control Method
(f = Monitor enabled,
Unit
× = Monitor disabled)
Open loop vector
*2
0.01%
f
0.01Hz
f
*3
0.1A
f
[No.]
f
*2
0.01%
f
0.1V
f
1V
f
0.1kW
f
0.1%
f
[Bit]
f
[Bit]
f
[Bit]
f
1H
f
[No.]
f
0.1%
f
0.1%
f
0.1%
f
0.1%
f
0.1%
f
*2
0.01%
f
0.01%
f
0.01%
f
0.1%
f
0.1%
f
0.1%
f
0.1%
f
0.1%
f
0.1V
f
0.1V
f
0.1deg
f
0.1deg
×
0.1deg
f
f
[Bit]
f
[Bit]
f
[Bit]
f
0.01%
f
0.01%
×
[Bit]
f
0.01%
f
[No.]
f
Pulse
×
0.1deg
f
0.01%
f
[BCD]
f
*1
Flux vector
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
×
f
f
f
f
f
f
f
f
f
f
f
f
f

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents