Constant
Name
No.
E1-01
Input voltage setting
E1-02
Motor capacity selection
E1-03
Motor rated voltage
E1-04
Motor rated current
E1-05
Number of motor poles
E1-06
Motor max. speed
E1-07
Motor base speed
E1-08
Motor min. speed
E1-09
Motor armature resistance
E1-10
Motor d-axis inductance
E1-11
Motor q-axis inductance
E1-13
Induced voltage
Variable torque/constant torque selec-
E1-14
tion
E1-15
Motor mechanical loss
E1-16
Motor wiring resistance
F1-01
PG constants
Operation selection at PG open-circuit
F1-02
(PGO) detection
Operation selection at overspeed (OS)
F1-03
detection
Operation selection at speed deviation
F1-04
(DEV) detection
F1-05
PG rotation direction
F1-08
Overspeed (OS) detection level
F1-09
Overspeed (OS) detection delay time
F1-10
Speed deviation (DEV) detection level
Speed deviation (DEV) detection
F1-11
delay time
PG open-circuit (PGO) detection delay
F1-13
time
F2-01
AI-14B input function selection
DI-08, DI-16H2 speed reference set-
F3-01
ting selection
F4-01
AO-08, 12CH1 output item selection
F4-02
AO-08, 12CH1 output gain
F4-03
AO-08, 12CH1 output bias
F4-04
AO-08, 12CH2 output item selection
F4-05
AO-08, 12CH2 output gain
F4-06
AO-08, 12CH2 output bias
F5-01
DO-02 CH1 output selection
F5-02
DO-02 CH2 output selection
Table A−5 Constants List (Cont'd)
Initial
User
Setting
Setting
*1 *2
200
*2 *3
*2 *3
*2 *3 *4
*2 *3
*2 *3
*2 *3
*2 *3
*2 *3
*2 *3
*2 *3
*2 *3
*2
0
*2
0.0
*2
1.0
1024
1
1
3
1
115
0.0
10
0.5
3.0
0
0
5
1.0
0.0
3
1.0
0.0
0
1
*1
Set value for 200V class. For 400V class, the value is twice as that of 200V class.
*2
Not initialized.
*3
Initial setting differs depending on motor capacity.
*4
0.01A for models of 7.5 kW or below.
*5
Initial settings in the parentheses are values obtained at 3-wire initialization.
Constant
Name
No.
F6-01
DO-08 output mode selection
Input level of external fault from trans-
F9-01
mission option
External fault from transmission op-
F9-02
tion
Operation at external fault input from
F9-03
transmission option
Trace sampling cycle of transmission
F9-04
option
Selection of torque reference from
F9-05
transmission option
Operation selection at BUS error
F9-06
detection
H1-01
Multi-function input (terminal 3-11)
H1-02
Multi-function input (terminal 4-11)
H1-03
Multi-function input (terminal 5-11)
H1-04
Multi-function input (terminal 6-11)
H1-05
Multi-function input (terminal 7-11)
H1-06
Multi-function input (terminal 8-11)
H2-01
Multi-function input (terminal 9-10)
H2-02
Multi-function input (terminal 25-27)
H2-03
Multi-function input (terminal 26-27)
H3-01
Signal level selection (terminal 13)
H3-02
Gain (terminal 13)
H3-03
Bias (terminal 13)
H3-04
Signal level selection (terminal 16)
Multi-function analog input (terminal
H3-05
16)
H3-06
Gain (terminal 16)
H3-07
Bias (terminal 16)
H3-08
Signal level selection (terminal 14)
Multi-function analog input (terminal
H3-09
14)
H3-10
Gain (terminal 14)
H3-11
Bias (terminal 14)
H3-12
Analog input filter time
H4-01
Monitor selection (terminal 21-22)
H4-02
Gain (terminal 21-22)
H4-03
Bias (terminal 21-22)
H4-04
Monitor selection (terminal 23-22)
H4-05
Gain (terminal 23-22)
H4-06
Bias (terminal 23-22)
H4-07
Analog output signal level selection
APPENDIX 4
CONSTANTS LIST
Initial
User
Setting
Setting
0
0
0
1
0
1
1
24
14
*5
3 (0)
*5
4 (3)
*5
6 (4)
*5
8 (6)
0
1
2
0
100.0
0.0
0
00
100.0
0.0
2
1F
100.0
0.0
0.00
5
1.0
0.0
3
1.0
0.0
1
87