Comm Link connection

A B C D E
COMM LINK
MLC 104 Plus Series
Right Side Panel
200' (61 m) max.
to Last Device
Extron CTLP Cable Color Code:
A
+12 VDC
B
Ground ( ) & Drain Wire
C
Control Module Communication
E
SCP Communication
N

MLS connection

A B C
MLC/IR
A
+12 VDC
B
Ground ( )
C
IRCM, ACM, RCM, CM
E
SCP communication (IR)
Maximum =
2 SCPs
Per System
When an SCP 104 is connected to one of
these controllers, the SCP's DIP switch #4
must be in the ON (up) position.
MediaLink
Switcher's
rear panel
MLC/IR port
Ground ( )
Receive (Rx)
Transmit (Tx)
B
Transmit (Tx)
Receive (Rx)
A
MLC 104 Plus Series • Hardware Setup
SCP 104
DISPLAY
ON
OFF
VOLUME
CONFIG
C
IRCM, ACM, RCM, CM
B
Ground ( )
A
+12 VDC
Maximum =
4 Control
Modules
(4 module
addresses)
= Red
= Black & Drain Wire
= Violet
= White
You must connect a ground wire
between the MLC and the MLS.
B
A
MLC 104 Plus Series
Right Side Panel
A B
MLS
RS-232
VCR
1
DVD
2
PC
3
4
SCP 104
DVD & VCR CONTROL
Tx
DVD
VCR
TITLE
MENU
TUNER
TV/VCR
ENTER
PREV/REW
PLAY NEXT/FWD PAUSE
STOP
IRCM-DV+
ON
1
2 3 4
2-9