Check List - Furuno FS-1570 Service Manual

Ssb radio telephone
Hide thumbs Also See for FS-1570:
Table of Contents

Advertisement

1. Check of installation
The cable must be fixed firmly and tidy.
No.
1.1
Do you understand the system configuration?
Mounting and wiring of transceiver, controller and power
supply unit
- All securing screws are fully tightened.
1.2
- Units are grounded.
- All connections are made correctly.
- All connecting wires are secured.
MF/HF TX/RX antenna
- The lead-in wire is secured without slack.
- The antenna does not touch to other objects such as mast,
derrick post and rigging.
1.3
- For safety, "WARNING: High voltage" sign and suitable guards
are provided to prevent personnel from coming in accidental
contact with dangerous voltage on the lead-in wire.
- The lead-in insulator is clean.
Antenna coupler AT-1560
- The grounding is connected securely.
- The antenna wire is secured.
1.4
- The shield of the coaxial cable and the control signal cable are
fabricated correctly and grounded.
- Wires and parts in the matching circuit are not touched each
other.
RX antenna (FAX-5)
1.5
- Check for grounding.
- Check for waterproofing.
NBDP terminal
1.6
When NBDP terminal is connected, optional NBDP DSP board is
installed.
W/R2 board for FS-2570
1.7
All connections are made on W/R2 board, if provided. When T/R
antenna is used, JP1 and JP2 on TX FIL board are changed.
ID, CS, AAB display
1.8
MMSI, CS, AAIC, AAB and ID are marked on the controller unit,
the terminal unit or nearby those units with labels.
Power supply unit
1.9
Check the power supply unit for power specification. Power
alteration includes the change of internal wiring and fuse.
Item to be checked
i

Check List

Result
Refer to
Chapter 1
Page 3-36
Page 3-34
Page 3-35