Alarm; Auto Ack; Erase; Message - Furuno FS-1570 Service Manual

Ssb radio telephone
Hide thumbs Also See for FS-1570:
Table of Contents

Advertisement

Table 3.3.1 lists the DSC SETUP Menus.
1

ALARM

2

AUTO ACK

3

ERASE

4

MESSAGE

5

POSITION

6

PRINT OUT

7

SCAN FREQ.

8
VOLUME
TEST
9
(PASSWORD)
SYSTEM
10
(PASSWORD)
Note)
1) Factory-default is screened.
2) *: "UNABLE REASON" is selected among;
NO REASON GIVEN(default), BUSY, EQUIP DISABLE,
MODE NOT USABLE and CH NOT USABLE.
Item
INTERNAL
RCVD CALL
AUDIO
OLD
ALARM
POSITION
POSITION OLDER
EXT ALARM
COMPLY TYPE
UNABLE REASON
POSITION CALL
POLLING CALL
RCVD ORDINARY LOG?
RCVD DISTRESS LOG?
TRANSMITTED LOG?
SEND MESSAGE?
Message file entry
INPUT TYPE
LAT
LON
TIME
XMIT CALL
RCVD CALL
DAILY TEST
ROUTIINE
DISTRESS
KEY CLICK
HANDSET
ORDINARY ALARM
DISTRESS ALARM
MMSI
LINE OUT
WATCH RCVR
CH DET S LEVEL
REGULATION
ON
ON
4.0,
3.0,
DITRS/
URG
UNABLE ABLE
See note)
ON
ON
AUTO
Valid when INPUT TYPE is MANUAL.
AUTO
AUTO
AUTO
F1-F6: OFF
2,8M: FIXED 4,6,12,16M: ON
ON
32
35
38
See page 6-15.
FIXED
+0.0 DB
MF/HF
100
(OFF – 255)
INTL
3-15
3.3 DSC SETUP
Table 3.3.1 DSC Set up menus
Option
OFF
OFF
2.0,
1.0,
0.5H
ALL
ROUTINE
OFF
OFF
See page 3-18.
See page 3-20.
MANUAL
MANUAL
MANUAL
MANUAL
OFF
(0-63)
(0-63)
(38-63)
(-4.5 - +4.5dB
1.5dB step)
MF
RUSSIA
OFF

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fs-2570

Table of Contents